Rapid Homogeneous Detection of Biological Assays Using Magnetic Modulation Biosensing System
Published on: June 13, 2010
Highly Sensitive and Specific Zika Virus Serological Assays Using a Magnetic Modulation Biosensing System
Yehudit Michelson1, Yaniv Lustig2, Shira Avivi1
1Faculty of Engineering, Bar-Ilan University, Ramat Gan, Israel.
Background:
Zika virus has created global alarm because it has been associated with catastrophic fetal abnormalities, including microcephaly, spontaneous abortion, and intrauterine growth restriction. Current serological assays that detect antiviral antibodies suffer from low sensitivity and high cross-reactivity among different flaviviruses.
Methods:
In this study, utilizing a novel magnetic modulation biosensing (MMB) system and the Zika nonstructural 1 protein, we show highly sensitive and specific Zika serological assays. We blindly tested 60 reverse-transcription polymerase chain reaction Zika-positive samples and healthy patients' serum samples, as well as 44 serum samples from enzyme-linked immunosorbent assay (ELISA) West Nile- and dengue-positive patients. The Zika-positive samples were collected from Israeli travelers returning from Zika-endemic areas.
Results:
The MMB Zika assays have 88%-97% sensitivity, much higher than the current state-of-the-art EUROIMMUN ELISA assays (38%-74%). In addition, the specificity is 100%, and the cross-reactivity with West Nile and dengue viruses is minimal (0%-4%). Furthermore, the MMB assays detected Zika IgM antibodies as early as 5 days and as late as 180 days postsymptoms onset, significantly extending the number of days that the antibodies are detectable.
Conclusions:
The sensitivity, specificity, and simplicity of the MMB assays may significantly improve Zika diagnosis and provide accurate results for public health agencies.
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
What are Viruses?
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or...
Magnetism
An individual magnetic pole cannot be isolated. No matter how small, every piece of a magnet contains a north pole and a south...
Introduction to Virus