Establishing the European diagnostic reference levels for interventional cardiology
T Siiskonen1, O Ciraj-Bjelac2, J Dabin3
1STUK - Radiation and Nuclear Safety Authority, P.O. Box 14, FI-00881 Helsinki, Finland.
Patient radiation doses in interventional cardiology are high. This study suggests European diagnostic reference levels (DRLs) for procedures like coronary angiography and TAVI to help reduce patient exposure and prevent radiation injuries.
Area of Science:
- Medical Physics
- Radiology
- Cardiology
Background:
- Interventional cardiac procedures can lead to significant patient radiation doses.
- High doses pose risks of radiation injuries, including skin erythema, cardiovascular tissue reactions, and secondary cancers.
- Standardized radiation dose metrics are needed for patient protection in interventional cardiology.
Purpose of the Study:
- To collect and analyze patient exposure data from interventional cardiology procedures across multiple countries.
- To propose European diagnostic reference levels (DRLs) for air kerma-area product for various interventional cardiac procedures.
- To emphasize the importance of DRLs as an optimization tool for reducing patient radiation exposure.
Main Methods:
- Collected patient exposure data from 13 countries, 37 clinics, and nearly 50 interventional rooms.
- Analyzed data from 14,922 interventional cardiology procedures, covering 10 different types of interventions.
- Calculated European diagnostic reference levels (DRLs) for air kerma-area product for specific procedures.
Main Results:
- Suggested European DRLs for coronary angiography (35 Gy cm²), percutaneous coronary intervention (85 Gy cm²), and transcatheter aortic valve implantation (130 Gy cm²).
- Established DRLs for electrophysiological procedures (12 Gy cm²), single-chamber (2.5 Gy cm²), dual-chamber (3.5 Gy cm²), and cardiac resynchronization therapy pacemakers (18 Gy cm²).
- Identified newer techniques like TAVI and chronic total occlusion (CTO) interventions as associated with higher radiation doses.
Conclusions:
- The proposed European DRLs provide a benchmark for patient exposure in interventional cardiology.
- DRLs are crucial for optimizing radiation protection and minimizing patient risks.
- Continuous monitoring and comparison of patient doses using DRLs are essential for improving safety in cardiac interventions.
More Related Videos
08:42Methods for Comparing Nutrients in Beebread Made by Africanized and European Honey Bees and the Effects on Hemolymph Protein Titers
Published on: March 17, 2015
11:00Establishment and Analysis of Tumor Slice Explants As a Prerequisite for Diagnostic Testing
Published on: November 29, 2018
Related Concept Videos
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions
Inertial Frames of Reference
Non-inertial Frames of Reference
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Community Based Intervention
Foundations of Community Mental Health Programs
Central to the success of community-based interventions is the...