Related Experiment Video
Updated: Feb 3, 2026

Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Ionic liquid-copolymerized monolith incorporated with zeolitic imidazolate framework-8 as stationary phases for
Zhenkun Mao1, Tao Bao1, Zhentao Li1
1Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Wuhan University School of Pharmaceutical Sciences, Wuhan, 430071, China.
Abstract:
A novel ionic liquid (1-allyl-methylimidazolium chloride, AlMeIm+Cl-) polymer monolith poly(ionic liquid-co-ethylene dimethacrylate) incorporated with zeolitic imidazolate framework-8 (ZIF-8-poly(IL-co-EDMA)) was firstly synthesized as stationary phases of monolithic column for capillary electrochromatography by one-step copolymerization. Incorporation of ZIF-8 into ionic liquid polymer monolith evidently enhanced the separation selectivity for four alkylbenzenes in reversed phase capillary electrochromatography (CEC), due to the synergistic effect derived from the same imidazole ring structure of ionic liquid and organic ligands of ZIF-8. Meanwhile, electroosmotic flow (EOF) was generated by ionic liquid in a wide range of pH values from 2.0 to 12.0. The resultant monolithic columns were characterized by scanning electron microscopy (SEM) and Fourier transform infrared (FT-IR). The results indicated that the prepared monolithic columns had good permeability and mechanism stability. The resultant monolithic columns were applied for the separation of neutral compounds, anilines and phenols. The highest column efficiency was 2.07 × 105 plates m-1 (theoretical plates, N) for toluene. Under optimal conditions, reproducibility was obtained with relative standard deviations (RSDs) of the retention time for run-to-run, day-to-day, column-to-column and batch-to-batch were in the range of 1.58 - 3.19%, 1.92 - 3.87%, 3.84 - 4.96% and 2.63 - 4.33%, respectively. Incorporation ZIF-8 into ionic liquid polymer monolith was a promising way for the application of new materials in the fabrication of novel monolithic columns.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Phase Diagrams
Phase Transitions
Phase Transitions: Sublimation and Deposition
Phase Transitions: Melting and Freezing
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...

