Related Experiment Video
Updated: Feb 3, 2026

Development of Sulfidogenic Sludge from Marine Sediments and Trichloroethylene Reduction in an Upflow Anaerobic Sludge Blanket Reactor
Published on: October 15, 2015
Development and optimization of a QuEChERS-GC-MS/MS methodology to analyse ultraviolet-filters and synthetic musks in
Sara Ramos1, Vera Homem1, Lúcia Santos1
1LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.
Abstract:
A Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) methodology followed by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) analysis was developed to extract synthetic musk compounds (SMCs) (6 polycyclic, 2 macrocyclic and 5 nitro musks) and ultraviolet-filters (UVFs) (6 compounds) from sludge. This methodology fills a gap in the literature, since the proposed technique does not require specific equipment, nor large amounts of solvents, sorbents and time to extract SMCs and UVFs from sludge. To optimize this new methodology, a design of experiments (DoE) approach was used, applying first a screening design (SD) and then a central composite design (CCD). The best conditions achieved to extract these 19 compounds simultaneously were: 500 mg freeze dried sludge, 2.5 min of vortex and 15 min ultrasound and the use of a QuEChERS for the dispersive solid-phase extraction (d-SPE) containing 500 mg MgSO4, 410 mg C18 and 315 mg PSA. Then, this methodology was successfully validated. Recoveries of the target compounds ranged from 75% (cashmeran, DPMI) to 122% (2‑ethylhexyl 4‑methoxycinnamate, EHMC), with good repeatability (relative standard deviation < 10%). The instrumental detection limits (IDLs) and quantification (IQLs) varied from 0.001 pg (musk moskene, MM) to 7.5 pg (musk xylene, MX) and from 0.003 (MM) to 25 pg (MX), respectively. The method detection and quantification limits (MDLs and MQLs) ranged between 0.5 (DPMI) and 1394 (exaltolide, EXA) ng/g dw and 2 and 4648 ng/g-dw, respectively. Both SMCs and UVFs were detected in all sludge samples analysed. Higher concentrations were found for octocrylene (OC: maximum value of 115,486 ng/g-dw) followed by galaxolide (HHCB: 81,771 ng/g-dw). Only the nitro musks ambrette, xylene, moskene and tibetene and macrocyclic musk ethylene brassylate (EB) were not detected in any sample.
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active Filters
Synthetic Biology
Golden rice
Golden rice is a genetically modified...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Synthetic Disvision of Polynomials