Pulse-Width Multiplexing ϕ-OTDR for Nuisance-Alarm Rate Reduction.
Xiang Zhong1, Xicheng Gao2, Huaxia Deng3
1School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Hefei 230009, China. zhx0325@hfut.edu.cn.
Sensors (Basel, Switzerland)
|October 21, 2018
Summary
This study introduces a pulse-width multiplexing method for phase-sensitive optical time-domain reflectometry (ϕ-OTDR). The technique significantly reduces nuisance alarms by fusing data from different pulse widths, improving perimeter protection systems.
Area of Science:
- Photonics and Optical Sensing
- Signal Processing
- Security Systems
Background:
- Phase-sensitive optical time-domain reflectometry (ϕ-OTDR) is crucial for detecting physical disturbances.
- High nuisance-alarm rates can limit the practical application of ϕ-OTDR systems, especially in perimeter protection.
- Optimizing signal-to-noise ratio (SNR) is key to improving the reliability of optical sensing.
Purpose of the Study:
- To develop and validate a novel pulse-width multiplexing method for reducing nuisance alarms in ϕ-OTDR.
- To investigate the impact of varying pulse widths on the SNR of ϕ-OTDR signals.
- To enhance the performance of ϕ-OTDR systems for reliable perimeter security.
Main Methods:
- A pulse-width multiplexing technique was implemented, injecting light pulses of varying widths into a sensing fiber.
- Data from different pulse widths were treated as outputs from multiple sensors and processed using a multisensor data fusion algorithm.
- A feature-layer algorithm based on Dempster-Shafer evidential theory utilized SNR as a key feature.
Main Results:
- Laboratory tests demonstrated a clear correlation between pulse width and the SNR of ϕ-OTDR data.
- A four-pulse-width multiplexing ϕ-OTDR system was constructed and tested.
- The proposed method achieved a significant reduction in the nuisance-alarm rate by approximately 70%.
Conclusions:
- The pulse-width multiplexing method effectively reduces nuisance alarms in ϕ-OTDR systems.
- The technique offers a simple yet powerful approach to enhance the reliability of optical sensing for perimeter protection.
- This method shows great potential for practical deployment in security applications.
More Related Videos
Related Concept Videos
Increased pulse rate
1.2K
Tachycardia is a condition marked by an abnormally fast or irregular heart rate, surpassing the typical resting rate. In adults, tachycardia is characterized by a pulse rate ranging from 100 to 180 beats per minute. The increased heart rate can result in inadequate blood flow to various body parts, ultimately diminishing the oxygen supply to organs and tissues.
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
Many factors can elevate the risk of developing tachycardia. These include advanced age, a family history of arrhythmias, and an...
1.2K
Decreased pulse rate
902
Bradycardia is a medical condition in which the heart rate is slower than normal. It occurs when the heart's natural pacemaker, the sinus node, generates slower electrical impulses than the standard rhythm. In adults, bradycardia is diagnosed when the pulse rate falls below 60 beats per minute, indicating a deviation from the normal heart rate range.
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
902
Pulse
2.1K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.1K
Pulse
3.8K
The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
3.8K
Oxidation-Reduction Reactions
75.7K
Oxidation–Reduction Reactions
75.7K
Measuring Reaction Rates
29.3K
Polarimetry finds application in chemical kinetics to measure the concentration and reaction kinetics of optically active substances during a chemical reaction. Optically active substances have the capability of rotating the plane of polarization of linearly polarized light passing through them—a feature called optical rotation. Optical activity is attributed to the molecular structure of substances. Normal monochromatic light is unpolarized and possesses oscillations of the electrical...
29.3K