Olga Volotskova1, Xuiqi Fang2, Michael Keidar2
1Department of Radiation Oncology, NYU Langone Medical Center & Laura and Isaac Perlmutter Cancer Center, New York, NY, 10016, USA.
Purpose:
To correlate the dose response and changes in microscopic structures of the radiochromic films exposed to the clinical magnetic field in the range 1.5-3 T with standard and flattening filter-free (FFF) photon beams.
Methods:
The radiochromic film was cut into 5 × 5 cm2 sheets/samples from one batch. These samples were exposed to a 1.5-T and/or 3-T B-fields from an MRI scanner using an abdominal sequence for 7 min before and after irradiation with 6 MV and/or 6 MV FFF beams. Films were placed in a reference condition at 5 cm depth in a solid water phantom and exposed up to 20 Gy. The sample orientation was maintained the same during exposure, readout, and scanning electron microscopic (SEM) analysis. The samples were scanned with an Epson Expression 11000XL in a 48-bit RGB color mode at 300 dpi with red channel. Scanned images were processed in Image J and red channel mean intensity values were recorded. The samples were then coated with 6 nm gold and imaged by SEM Teneo (5 kV, 13 pA) under 2000, 2500, and 3000 magnifications for texture analysis.
Results:
The changes in the microstructure of the films in magnetic fields (1.5- and 3.0-T) were dose dependent. The orientation and granular size of samples at higher doses were altered compared to the controls. Needle-shaped structures of the active layer were longer and aligned for samples exposed to higher doses and magnetic field. However, no significant changes in optical density due to the presence of a magnetic field pre/postirradiation up to 20 Gy were observed.
Conclusion:
Fine structures of the film represent the polymerization characteristics that are affected by the radiation dose in the magnetic field. Upon exposure to radiation, diacetylene monomers undergo polymerization that forms longer chains with a temporal response. Even though this study did not notice any significant changes in optical density due to the presence of magnetic field, this should be studied in simultaneous application of the magnetic field during treatment in a dedicated MR-linac unit.
More Related Videos
Related Concept Videos
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...
Magnetic Field Of A Current Loop
Magnetic Field due to Moving Charges
Consider a point charge moving with a constant velocity. Like the electric field, the magnetic field at any point is directly proportional to the magnitude of the charge and inversely proportional to the square of the distance between the source point and the field point. However, unlike the electric field, the magnetic field is always perpendicular to the plane containing the line...