Related Experiment Video
Updated: Feb 3, 2026

An Improved Method for Collection of Cerebrospinal Fluid from Anesthetized Mice
Published on: March 19, 2018
Competitive method for fluorescent dopamine detection in cerebrospinal fluid based on the peroxidase-like activity of
Ying Shi1, Yanjiao Pang1, Ning Huang2
1Key Laboratory of Luminescent and Real-Time Analytical Chemistry, Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China.
Abstract:
Dopamine (DA), a catecholamine neurotransmitter, is considered to be an important indicator for mental diseases detection in the clinic. In this study, a novel fluorescent sensing platform consisting of the ficin-H2O2-tyramine system for determining DA in cerebrospinal fluids (CSF) was established. The proposed method is based on the fact that ficin, a mimetic peroxidase, can catalyze H2O2 decomposition into OH radicals, which can oxidize non-fluorescent tyramine into fluorescent dityramine. When DA was introduced, DA can compete with tyramine for OH and resulting in the oxidation reaction of tyramine inhibited along with the fluorescence intensity of the system decreased, which provides a unique strategy for fluorescence detection of DA. Under optimal conditions, the fluorescence intensity decreased linearly with the DA level over a wide concentration range from 0.05 to 12.0 μM (R2 = 0.995) with a detection limit of 46 nM (3σ/k). More importantly, the proposed sensing approach exhibits high sensitivity, good selectivity and has been successfully applied to DA sensing in complex biological samples, which made it hold great potential for DA determination in chemical and biological analytical applications.
Related Concept Videos
Cerebrospinal Fluid
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
Competition
Acid–Base Equilibria: Activity-Based Definition of pH
In solutions of very low ionic strength—for example, pure water—the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
The Fluid Mosaic Model
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

