Related Experiment Video
Updated: Feb 3, 2026

07:16
Biochemical Titration of Glycogen In vitro
Published on: November 24, 2013
28.9K
Towards Green Titration: Batchwise Titration with Reusable Solid Sorbed Indicators
Miki Kanna1, Sarawut Somnam1, Wasin Wongwilai2,3
1Department of Chemistry, Faculty of Science, Chiang Mai University.
Summary
Reusable solid-supported indicators were developed for greener acid-base titrations, reducing chemical waste. These novel materials were successfully applied to analyze real-world samples like vinegar and fruit juice.
Area of Science:
- Analytical Chemistry
- Green Chemistry
Background:
- Traditional acid-base titrations often involve significant chemical usage and waste generation.
- Developing sustainable analytical methods is crucial for environmental protection and resource conservation.
Purpose of the Study:
- To create reusable indicator-sorbed solids for green analytical chemistry applications.
- To reduce chemical consumption in acid-base titrations through solid-supported indicators.
Main Methods:
- Sorption of indicators (phenolphthalein, thymol blue, butterfly pea flower extract) onto solid supports (anion-exchange resins, kaolin).
- Application of these indicator-sorbed solids in acid-base titrations in aqueous and aqueous-organic phases.
- Testing the developed methods on real samples including vinegar, colored fruit juice, and vegetable oil.
Main Results:
- Successfully developed reusable indicator-sorbed solids.
- Demonstrated the efficacy of these solids in acid-base titrations across different phases.
- Validated the application of the developed techniques on diverse real-world samples.
Conclusions:
- Reusable indicator-sorbed solids offer a promising approach for greener analytical chemistry.
- The developed methods effectively reduce chemical waste in acid-base titrations.
- Solid-supported indicators are viable for analyzing complex real samples.
Related Concept Videos
Titration of a Polyprotic Acid
105.2K
A polyprotic acid contains more than one ionizable hydrogen and undergoes a stepwise ionization process. If the acid dissociation constants of the ionizable protons differ sufficiently from each other, then the titration curve for such polyprotic acid generates a distinct equivalence point for each of its ionizable hydrogens. Therefore, titration of a diprotic acid results in the formation of two equivalence points, whereas the titration of a triprotic acid results in the formation of three...
105.2K
Acid-Base Titration Curves
141.2K
A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of...
For a titration carried out for 25.00 mL of...
141.2K
Indicators
60.9K
Certain organic substances change color in dilute solution when the hydronium ion concentration reaches a particular value. For example, phenolphthalein is a colorless substance in any aqueous solution with a hydronium ion concentration greater than 5.0 × 10−9 M (pH < 8.3). In more basic solutions where the hydronium ion concentration is less than 5.0 × 10−9 M (pH > 8.3), it is red or pink. Substances such as phenolphthalein, which can be used to determine the pH of a solution, are...
60.9K
Titration Calculations: Weak Acid - Strong Base
49.3K
Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
49.3K
Titration Calculations: Strong Acid - Strong Base
33.9K
Calculating pH for Titration Solutions: Strong Acid/Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
33.9K
Redox Titration: Overview
5.0K
Redox titration is a chemical analysis technique used to determine the concentration of an unknown substance by measuring the electron transfer in a redox (reduction-oxidation) reaction. The process involves gradually adding a titrant with a known concentration of an oxidizing or reducing agent, to the analyte, the solution with an unknown concentration, until reaching the endpoint, which indicates the completion of the reaction between the two substances. Ensuring the analyte is in a single...
5.0K