Related Experiment Video
Updated: Feb 3, 2026

Robotic-Guided Stereoelectroencephalography for Invasive Epilepsy Monitoring
Published on: June 13, 2025
Stereo-electroencephalography-guided radiofrequency thermocoagulation in patients with focal epilepsy: A systematic
Pierre Bourdillon1,2, Michel Cucherat2,3,4, Jean Isnard5,6
1Department of Functional Neurosurgery, Hospices Civils de Lyon, Lyon, France.
Objective:
Despite the increasing number of studies reporting results of stereo-electroencephalography (SEEG)-guided radiofrequency-thermocoagulation (SEEG-guided RF-TC) in the treatment of patients with drug-resistant focal epilepsy, the exact efficacy of this approach remains unclear. The seizure-freedom rate varies greatly across studies and the factors associated with efficacy have not been formally investigated.
Methods:
All prospective or retrospective studies reporting efficacy and/or safety of SEEG-guided RF-TC in patients with drug-resistant focal epilepsy were included. The primary outcome was the seizure-free rate 1 year after the procedure. Secondary outcomes were (1) the responder rate 1 year after the procedure and (2) the proportion of patients with permanent neurologic deficit 1 year after the procedure. Each outcome was assessed in all patients and in 4 groups of patients defined by the etiology of epilepsy. Each outcome was pooled using inverse variance weighting, logit transformation of proportion, and a random-effects model.
Results:
No prospective study was identified and a total of 6 retrospective studies, reporting efficacy and safety data of 296 patients, were included. The pooled rate of permanent neurologic deficit was 2.5% (95% confidence interval [CI] 1.2%-5.3%), without heterogeneity across studies. In contrast, both the seizure-free and responder rates varied greatly across studies, and statistical heterogeneity was high. The pooled seizure-free and responder rates were 23% (95% CI 8%-50%) and 58% (95% CI 36%-77%), respectively. Both for the seizure-free and responder rates, the greatest efficacy was observed in patients with periventricular nodular heterotopia and the lowest in patients with normal magnetic resonance imaging (MRI) findings.
Significance:
SEEG-guided RF-TC is a safe procedure with low risk of complications. In contrast, the level of evidence regarding its efficacy remains low. Better identification of factors associated with seizure outcome are needed.
More Related Videos
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016
09:32Network Analysis of Foramen Ovale Electrode Recordings in Drug-resistant Temporal Lobe Epilepsy Patients
Published on: December 18, 2016
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Random and Systematic Errors
Directing Effect of Substituents: meta-Directing Groups
Systematic Sampling Method
Systematic sampling is one of the simplest methods...
Epilepsy and Seizures: Overview
Various factors can trigger epilepsy, including genetic factors, brain damage, metabolic causes, and unknown etiology. Diagnosis of epilepsy involves electroencephalography (EEG), which...