Approaching Standardless Quantitative Elemental Analysis of Solids: Microsecond Pulsed Glow Discharge and
Abstract:
Among various ionization sources for mass spectrometry, microsecond pulsed glow discharge (MP-GD) and buffer-gas-assisted laser ionization (BGA-LI) sources have the potential for direct quantitative elemental analysis of solids without the requirement of standard reference materials. The analytical potential of these two ionization sources has been evaluated by coupling them to orthogonal time-of-flight mass spectrometry (MS). A straightforward method was proposed to achieve the quantitative result: if a spectrum contains little interference and elemental peak currents are proportional to their concentrations, then the molar concentration of each element is equal to its ion current proportion in the total ion current. Two series of metal standards were applied for the evaluation. Explicit spectra with little interference can be acquired by both techniques. The interferences contribute only a very small portion to the total ion current for MP-GD-MS and BGA-LI-MS; therefore, their influence on the quantitative result can be ignored. All metal elements can be determined quite accurately by the proposed quantitation method, while gaps exist for nonmetal elements due to the high ionization potentials or gas species interference. Between the two techniques, BGA-LI-MS offers a more accurate quantitative result, primarily due to its higher plasma temperature.
More Related Videos
08:51Profiling of Permethylated Mucin O-glycans Using Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry
Published on: June 20, 2025
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Matrix-Assisted Laser Desorption Ionization (MALDI)
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Ionization Energy
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...