Related Experiment Video
Updated: Feb 3, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Accuracy of flapless immediate implant placement in anterior maxilla using computer-assisted versus freehand surgery:
Zhaozhao Chen1,2, Junying Li1,2, Khaled Sinjab2
1State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
Objective:
To compare the accuracy of computer-guided surgery and freehand surgery on flapless immediate implant placement (IIP) in the anterior maxilla.
Material And Methods:
In this split-mouth design, 24 maxillary incisors in eight human cadaver heads were randomly divided into two groups: computer-guided surgery (n = 12) and freehand surgery (n = 12). Preoperatively, cone-beam computed tomography (CBCT) scans were acquired, and all implants were planned with a software (Blue Sky Plan3). Then, two types of surgeries were performed. To assess any differences in position, the postoperative CBCT was subsequently matched with the preoperative planning. For all the implants, the angular, global, depth, bucco-lingual, and mesio-distal deviations between the virtual and actual implant positions were measured.
Results:
A significant lower mean angular deviation (3.11 ± 1.55°, range: 0.66-4.95, p = 0.002) and the global deviation at both coronal (0.85 ± 0.38 mm, range: 0.42-1.51, p = 0.004) and apical levels (0.93 ± 0.34 mm, range: 0.64-1.72, p < 0.001) were observed in the guided group when compared to the freehand group (6.78 ± 3.31°, range: 3.08-14.98; 1.43 ± 0.49 mm, range: 0.65-2.31, and 2.2 ± 0.79 mm, range: 1.01-4.02). However, the accuracy of these two approaches was similar for the depth (p = 0.366). In the buccal direction, the mean deviations of both groups showed a general tendency of implants to be positioned facially, occurring more in implants of the freehand group.
Conclusion:
In flapless IIP, computer-guided surgery showed superior accuracy than freehand surgery in transferring the implant position from the planning. However, even with the help of a guide, the final fixture position tends to shift toward a facial direction.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Muscles of the Anterior Neck

