Related Experiment Video
Updated: Feb 3, 2026

Procoagulant Platelet Characterization by Measuring Phosphatidylserine Exposure and Microvesicle Release from Human Purified Platelets
Published on: November 29, 2024
Blood collection, platelet isolation and measurement of platelet count and size in mice-a practical guide
Katja Aurbach1, Markus Spindler1, Elizabeth J Haining2
1a Institute of Experimental Biomedicine I, University Hospital and Rudolf Virchow Center , University of Würzburg , Würzburg , Germany.
Abstract:
Inherited or acquired disorders of platelet production and function can result in thrombocytopenia and bleeding. Mouse models have proven useful for investigating the mechanisms that underlie these defects in humans. Precise methods for blood withdrawal, platelet isolation and measurement of platelet parameters are key for the generation of reproducible and conclusive data. Here, we provide three different protocols for mouse platelet isolation to encourage research knowledge transfer between experienced laboratories, while at the same time enabling less experienced researchers to implement a protocol that best suits their local expertise and equipment. We also address the issue that reported mouse platelet count and size vary considerably in the literature by investigating different factors that influence these important platelet parameters, namely: 1) genetic background and gender, 2) choice of analysis method (hematological analyzer or flow cytometry), 3) dilution of the blood sample and 4) choice of anticoagulant. The herein presented results and considerations may serve as a practical guide for both experienced and new researchers in the platelet field.
Related Concept Videos
Structure and Function of Platelets
Platelets are continually replenished, circulating in the bloodstream for 9-12 days before being removed by phagocytes, primarily in the spleen. A microliter of circulating blood contains between 150,000 and 450,000...
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...

