Gas Chromatography-Mass Spectrometry (GC-MS) and Gas Chromatography-Infrared (GC-IR) Analyses of the Chloro-1-
Karim M Abdel-Hay1,2,3, Tarek S Belal3, Younis Abiedalla1,4
11 Department of Drug Discovery and Development, Harrison School of Pharmacy, Auburn University, Auburn, AL, USA.
Abstract:
The analytical differentiation of the indole ring regioisomeric chloro-1- n-pentyl-3-(1-naphthoyl)-indoles is described in this report. The regioisomeric chloroindole precursor compounds, N- n-pentyl chloroindole synthetic intermediates, and the target chloro-substituted naphthoylindoles showed the equivalent gas chromatographic elution order based on the position of chlorine substitution on the indole ring. The regioisomeric chloro-1- n-pentyl-3-(1-naphthoyl)-indoles yield electron ionization mass spectra having equivalent major fragments resulting from cleavage of the groups attached to the central indole nucleus. Fragment ions occur at m/z 127 and 155 for the naphthyl and naphthoyl cations common to all indoles having the naphthoyl group substituted at the indole-3 position. Fragments resulting from the loss of the naphthoyl and/or n-pentyl groups from the molecular radical cation yield the cations at m/z 318, 304, 248, and 178. The characteristic (M-17)+ fragment ion at m/z 358 resulting from the loss of OH radical is significant in the mass spectra of all these compounds with 1-naphthoyl groups substituted at the indole-3 position. The vapor phase infrared spectra provide a number of characteristic absorption bands to identify the individual isomers.
More Related Videos
08:15Metabolomic Analysis of Barley by Gas Chromatography/Mass Spectrometry
Published on: November 8, 2024
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...