Related Experiment Video
Updated: Feb 3, 2026

Diagnostic Necropsy and Selected Tissue and Sample Collection in Rats and Mice
Published on: August 7, 2011
Enantioselective analysis of pheniramine in rat using large volume sample stacking or cation-selective exhaustive
Yaqi Yao1, Bo Zhang1, Shuang Li1
1School of Pharmacy, Shenyang Pharmaceutical University, Wenhua Road 103, Shenyang, Liaoning Province, PR China.
Abstract:
For the aim of simultaneously performing the enantioseparation and determination of the trace enantiomers in plasma samples, enantioseparation by HPLC using five kinds of chiral stationary phases were initially investigated. But unfortunately, enantioseparation could not be detected in reversed mobile phase mode with all the five columns. For this reason, two simple, economical and highly efficient online preconcentration methods, large volume sample stacking and sweeping (LVSS-sweeping) and cation-selective exhaustive injection and sweeping (CSEI-sweeping) both followed by the cyclodextrin modified electrokinetic chromatography (CDEKC) were examined in the present work. Parameters affecting the enantioseparation and enhancement efficiency of these two injection modes were monitored in detail, and migration order of the two enantiomers was identified by circular dichroism (CD) and HPLC. Upon optimization, two enantiomers were best separated with the improvement of sensitivity reaching 160-fold and 4000-fold respectively for LVSS-sweeping and CSEI-sweeping comparing with the normal CDEKC separation. Then the optimal condition of CSEI-sweeping-CDEKC was validated and showed high sensitivity (10 ng/mL for lower limit of quantification, LLOQ), satisfactory accuracy (96.8-111.6%) and precision (relative standard deviation, RSD within 9.4%). This demonstrated it to be a suitable strategy for the rapid enantioselective determination and quantitative analysis of pheniramine enantiomers in plasma samples. Therefore, the method was further applied in the enantiomeric analysis of pheniramine in rat pharmacokinetics and plasma protein binding investigations. Stereoselectivity in pharmacokinetics as well as plasma protein binding were observed, suggesting that the stereoselective protein binding might be responsible for the stereoselectivity in pharmacokinetics.
More Related Videos
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Qualitative Analysis
For instance, group IV...

