Related Experiment Video
Updated: Feb 3, 2026

Author Spotlight: Advancements in DNA Nanosensors – Addressing Sensitivity and Selectivity Challenges in Molecular Detection
Published on: February 9, 2024
Graphitic C3N4 nanosheet and hemin/G-quadruplex DNAzyme-based label-free chemiluminescence aptasensing for biomarkers
Ke Li Lin1, Tong Yang2, Hong Yan Zou2
1Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
Abstract:
Here we first reported that graphitic carbon nitride nanosheet (g-C3N4 NS) could effectively quench the chemiluminescence (CL) of luminol-hydrogen peroxide (H2O2) system. According to the new discovery, a label-free and homogeneous CL aptasensing platform was designed for sensitive detecting of biomarkers. In the absence of target, DNA probe containing hemin/G-quadruplex DNAzyme structure was adsorbed on the surface of g-C3N4 NS, causing the CL quenching of luminol through an electron transfer process. However, in the presence of the target, a DNA-DNA duplex was formed due to DNA hybridization reaction and target recognition effect, which could not be adsorbed onto the g-C3N4 NS surface because of its weak affinity. Thus, the electron transfer was blocked and the CL emission of luminol could be enhanced. The proposed CL aptasensor could detect carcinoembryonic antigen (CEA) with a detection limit of 63.0 pg/mL and it can also be used as a general detecting strategy for adenosinetriphosphate (ATP) detection. This aptasensing platform exhibited high sensitivity toward biomarkers and the probe need not be labeled, showing great promise for disease diagnosis.
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Labeling Emotion
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
Base Excision Repair
The first step of...
Weak Base Solutions