Background:
Fluoroscopic guidance is routinely utilized during hip arthroscopic surgery. Previous studies have shown that the C-arm orientation can significantly affect radiation exposure for both the surgeon and the patient during orthopaedic procedures. However, this has not been previously assessed for hip arthroscopic surgery.
Hypothesis:
Using an inverted C-arm during hip arthroscopic surgery will reduce radiation exposure to the patient and surgeon.
Study Design:
Descriptive laboratory study.
Methods:
A simulation study measured scatter radiation during hip arthroscopic surgery performed in the supine position under fluoroscopic guidance with an anthropomorphic pelvic phantom on a radiolucent operating table. Radiation exposure tested 2 different C-arm orientations: standard and inverted. Testing was performed at 6 locations corresponding to the patient, surgeon's neck, surgeon's waist, surgical technician, anesthesiologist, and radiology technician. Statistical analysis was performed using univariate and multivariate analyses assessing radiation exposure between the C-arm orientations. A risk calculation for carcinogenesis was performed based on reported radiation dosages.
Results:
Radiation exposure (in mGy/min) was more than 100-fold higher for the patient compared with the surgeon in both C-arm orientations. The inverted C-arm orientation resulted in a 2.48-fold decrease in patient radiation exposure when compared with the standard orientation (10.8 mGy/min vs 26.8 mGy/min, respectively). There was a small but significant increase in surgeon radiation exposure in the inverted orientation compared with the standard orientation (0.072 vs 0.067 mGy/min, respectively). The patient's carcinogenesis risk was decreased 2.64-fold with the inverted orientation compared with the standard orientation (1.4 × 10-5 vs 3.7 × 10-5, respectively).
Conclusion:
The inverted C-arm orientation resulted in a 2.48-fold decrease in patient radiation exposure with a 2.64-fold decrease in the carcinogenesis risk compared with the standard orientation. Inadvertently, the inverted orientation provided a 9-cm increase in the surgeon's working area. Our data supported the clinical utilization of the inverted C-arm orientation during hip arthroscopic surgery to minimize patient radiation exposure. Although there was a minimal but significant increase in surgeon radiation exposure with the inverted orientation, we believe that this is negligible when incorporated with standard leaded protective equipment as contrasted with the significant dose reduction for the patient as well as the decreased risk of carcinogenesis and hereditary disorders.
Clinical Relevance:
Patients undergoing hip arthroscopic surgery routinely acquire radiation exposure during the use of the C-arm. Measures to minimize radiation via the inverted C-arm orientation will decrease the unnecessary risk to the patient while continuing to allow for optimal treatment.
More Related Videos
06:28Decellularization of Whole Human Heart Inside a Pressurized Pouch in an Inverted Orientation
Published on: November 26, 2018
05:47Simulation of a Scaled Assembly Process with Collaboration of a Robotic Arm and Monitoring through a Vision System for Quality Control
Published on: August 29, 2025
Related Concept Videos
Inverting and Non-inverting OpAmps
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
Location and Orientation of the Heart
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
Karyotyping
Chromosome Structure
The centromere is a DNA sequence that links sister chromatids. This is also where kinetochores, protein complexes to which spindle microtubules attach, are constructed after the chromosome is replicated. The kinetochores allow the spindle microtubules to move the chromosomes within the cell during cell division.
Telomeres consist of non-coding repetitive nucleotide...