A multicenter study to evaluate automated platelet aggregometry on Sysmex CS-series coagulation analyzers-preliminary
Sean Platton1, Áine McCormick2, Musfira Bukht1
1The Royal London Hospital Haemophilia Centre Barts Health NHS Trust The Royal London Hospital London UK.
Background And Objectives:
Investigations of platelet function by light transmission aggregometry (LTA) using a dedicated aggregometer is time consuming and labor intensive. This multicenter study evaluated an automated LTA method using a coagulation analyzer to establish reference ranges and ideal testing regimen.
Methods:
Sysmex CS-2x00 series analyzers were used to measure aggregation using a range of agonists and concentrations: ADP (1-20 μM); arachidonic acid (0.5-1.5 mM); collagen (1.25-5 μg/mL); ristocetin (0.5-1.5 g/L); epinephrine (5-10 μM); TRAP (1-20 μM); U46619 (1 μM); and saline. Maximum and final aggregation, disaggregation, slope, and acquisition time were compared for each.
Results:
For 42 normal subjects there was no significant difference in aggregation parameters for: 10 μM and 20 μm ADP; 2 and 2.5 μM ADP; 1 and 1.5 mM arachidonic acid; 2.5 and 5 μg/mL collagen; 1 and 1.25 μg/mL collagen; 1.25 and 1.5 g/L ristocetin; 5 and 10 μM epinephrine; 5 and 10 μM or 20 μM TRAP. Maximum aggregation was reached by 300 seconds with 20 and 10 μM ADP, 1 μM U46619, 1 and 1.25 μg/mL collagen, 1.5 g/L ristocetin and 5, 10, and 20 μM TRAP: all others agonists required 600s.
Conclusions:
A standard panel of agonists can be used on the Sysmex CS-2x00 series analyzers: ADP (10, 5, 2.5, and 1.25 μM); 1 mM arachidonic acid; 1 μM U46619; 2.5 and 1.25 μg/mL collagen; 1.25 and 0.5 g/L ristocetin; 5 μM epinephrine; 5 and 10 μM TRAP; and saline. Aggregation should be observed for 600 seconds for all agonists except TRAP and U46619, which require 300 seconds. If further studies confirm these concentrations detect platelet disorders then Sysmex CS-series analyzers could replace dedicated aggregometers, or perform LTA where it is currently not available.
More Related Videos
05:49Procoagulant Platelet Characterization by Measuring Phosphatidylserine Exposure and Microvesicle Release from Human Purified Platelets
Published on: November 29, 2024
09:13Turbidimetry on Human Washed Platelets: The Effect of the Pannexin1-inhibitor Brilliant Blue FCF on Collagen-induced Aggregation
Published on: April 6, 2017
Related Concept Videos
Coagulation
Coagulation
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
Finding the Center of Gravity
Resistors In Series
In a series circuit, the...
Series Resonance
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...