[Slight Damage to Epidural Catheter Equipped with Tuohy Needle at Time of Insertion Results in Embedded Remnant.]
Abstract:
It is known that a portion of an epidural catheter can remain embedded when the catheter is pulled back at the time of insertion or a longer length than required is used. We report a case in which an epi- dural catheter piece including a metal coil broke off and remained embedded at the time of withdrawal. Because of the presence of the coil, MRI could not be utilized, while CT scanning was useful to locate the remaining portion. Following surgical extraction, the embedded portion was thoroughly examined. The point of the catheter was cut sharply, which suggested that damage occurred without awareness of the anesthesi- ologist When a catheter breaks leaving a remnant surgical extraction should be considered based on appropriate examination findings.
More Related Videos
Related Concept Videos
Leveling Equipment
Personal Protective Equipment
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Handwashing I: Introduction and Types of Equipment
Hand wash basins in clinical areas should have faucets that can be turned on and off without using the hands; that is, they should be non-touch or lever-operated....