Related Experiment Video
Updated: Feb 3, 2026

Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis
Published on: September 26, 2018
Validating Publicly Available Crosswalks for Translating ICD-9 to ICD-10 Diagnosis Codes for Cardiovascular Outcomes
Jesse A Columbo1,2,3,4,5, Ravinder Kang2,3,4,5, Spencer W Trooboff2,3,4,5
1Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH (J.A.C., P.P.G.).
Abstract:
Background On October 1, 2015, the Center for Medicare and Medicaid Services transitioned from the International Classification of Diseases, Ninth Revision ( ICD-9) to the ICD, Tenth Revision ( ICD-10) compendium of codes for diagnosis and billing in health care, but translation between the two is often inexact. Here we describe a validated crosswalk to translate ICD-9 codes into ICD-10 codes, with a focus on complications after carotid revascularization and endovascular aortic aneurysm repair. Methods and Results We devised an 8-step process to derive and validate ICD-10 codes from existing ICD-9 codes. We used publicly available sources, including the General Equivalence Mapping database, to translate ICD-9 codes used in prior work to ICD-10 codes. We defined ICD-10 codes as validated if they were concordant with the initial ICD-9 codes after manual comparison by two physicians. Our primary validation measure was the percent of valid ICD-10 codes out of the total ICD-10 codes obtained during translation. We began with 126 ICD-9 diagnosis codes used for complication identification after carotid revascularization procedures, and 97 ICD-9 codes for complications after endovascular aortic aneurysm procedures. Translation generated 143 ICD-10 codes for carotid revascularization, a 14% increase from the initial 126 codes. Manual comparison demonstrated 98% concordance, with 99% agreement between the reviewers. Similarly, we identified 108 ICD-10 codes for endovascular aortic aneurysm repair, an 11% increase from the initial 97 ICD-9 codes. We again noted excellent concordance and agreement (98% and 100%, respectively). Manual review identified 4 ICD-10 codes incorrectly translated from ICD-9 codes for carotid revascularization, and 3 codes incorrectly translated for endovascular aortic aneurysm repair. Conclusions Algorithms to crosswalk lists of ICD-9 codes to ICD-10 codes can leverage electronic resources to minimize the burden of code translation. However, manual review for code validation may be necessary, with collaboration across institutions for researchers to share their efforts.
More Related Videos
06:55Inverse Probability of Treatment Weighting Propensity Score using the Military Health System Data Repository and National Death Index
Published on: January 8, 2020
10:21Cell Based Assays of SINEUP Non-coding RNAs That Can Specifically Enhance mRNA Translation
Published on: February 1, 2019
Related Concept Videos
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
lncRNA - Long Non-coding RNAs
Reliability and Validity
Translation
Translation is the process of synthesizing proteins from the genetic information carried by messenger RNA (mRNA). Following transcription, it constitutes the final step in the expression of genes. This process is carried out by ribosomes, complexes of protein and specialized RNA molecules. Ribosomes, transfer RNA (tRNA), and other proteins produce a chain of amino acids—the polypeptide—as the end product of translation.
Translation Produces the Building Blocks of...
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...