Thrombus Volume as a Predictor of Nonrecanalization After Intravenous Thrombolysis in Acute Stroke

Joonsang Yoo1,2, Jang-Hyun Baek1,3, Hyungjong Park1

  • 1From the Department of Neurology (J.Y., J.-H.B., H.P., D.S., K.K., I.G.H., Y.D.K., K.-Y.L., H.S.N., J.H.H.).

Stroke
|October 26, 2018
PubMed

Background and Purpose- We investigated whether measuring the volume and density of a thrombus could predict nonrecanalization after intravenous thrombolysis. Methods- This study included a retrospective cohort to develop a computed tomography marker of thrombus for predicting nonrecanalization after intravenous thrombolysis and a prospective multicenter cohort for validation of this marker. The volume and density of thrombus were measured semiautomatically using 3-dimensional software on a baseline thin-section noncontrast computed tomography (1 or 1.25 mm). Recanalization was assessed on computed tomography angiography or magnetic resonance angiography immediately after intravenous thrombolysis or conventional angiography in patients who underwent further intra-arterial treatment. Nonrecanalization was defined as a modified Thrombolysis in Cerebral Infarction grade 0, 1, 2a. Results- In the retrospective cohort, 162 of 214 patients (76.7%) failed to achieve recanalization. The thrombus volume was significantly larger in patients with nonrecanalization than in those with successful recanalization (149.5±127.6 versus 65.3±58.3 mm3; P<0.001). In the multivariate analysis, thrombus volume was independently associated with nonrecanalization ( P<0.001). The cutoff for predicting nonrecanalization was calculated as 200 mm3. In the prospective multicenter validation study, none of the patients with a thrombus volume ≥200 mm3 among 78 enrolled patients achieved successful recanalization. The positive and negative predictive values were 95.5 and 29.4 in the retrospective cohort 100 and 23.3 in the prospective validation cohort, respectively. The thrombus density was not associated with nonrecanalization. Conclusions- Thrombus volume was predictive of nonrecanalization after intravenous thrombolysis. Measurement of thrombus volume may help in determining the recanalization strategy and perhaps identify patients suitable for direct endovascular thrombectomy.

Related Concept Videos

Regulation of Stroke Volume01:27

Regulation of Stroke Volume

The regulation of stroke volume, which is the amount of blood the heart pumps out during each heartbeat, is critical for maintaining a healthy circulatory system. Stroke volume is influenced by three main factors: preload, contractility, and afterload.
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
5.2K
Cardiac Output and Stroke Volume01:11

Cardiac Output and Stroke Volume

Cardiac output (CO) is an integral aspect of human physiology, reflecting the heart's efficiency and responsiveness to the body's needs. It represents the volume of blood that the left or right ventricle ejects into the aorta or pulmonary trunk each minute. The CO is calculated by multiplying the heart rate (HR)—the number of heartbeats per minute—by the stroke volume (SV)—the amount of blood pumped out with each heartbeat.
In an average resting adult male, the typical cardiac...
4.9K
Cardiac Output II: Effect of Stroke Volume on Cardiac Output01:22

Cardiac Output II: Effect of Stroke Volume on Cardiac Output

Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
3.4K
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.8K