Related Experiment Video
Updated: Feb 3, 2026

Author Spotlight: Advancements in Retroperitoneal Approach for Necrotizing Pancreatitis
Published on: March 15, 2024
Robotic Single-Site Sacrocolpopexy with Retroperitoneal Tunneling
Juan Liu1, Elise Bardawil1, Robert K Zurawin2
1Section of Minimally Invasive Gynecologic Surgery.
Introduction:
This series of cases was an investigation of the safety and feasibility of robotic laparoendoscopic single-site surgery (R-LESS) as a method of performing sacrocolpopexy.
Case Presentation:
This is a retrospective series of 15 cases of R-LESS sacrocolpopexy with the V-Loc (Medtronic, Minneapolis, Minnesota, USA) suture and a retroperitoneal tunneling technique performed by a single surgeon, combined with a literature review. Patient demographic information and perioperative data were analyzed. The standard robotic sacrocolpopexy steps were followed, but the surgeon used a combined technique of V-Loc suture and retroperitoneal tunneling to simplify the procedure. No additional ports were necessary in any of the patients.
Management And Outcome:
Using the pelvic organ prolapse quantification (POP-Q) scoring method, the mean preoperative C-point of the 15 patients was +1.16 compared to the mean immediate postoperative C-point, which was -5.5. The mean total sacrocolpopexy time was 74.7 (range, 50-99) minutes and mean mesh anchoring time was 22.60 ± 3.85 minutes. The mean sacral promontory fixation and tunneling and mesh position times were 11.87 ± 3.02 and 5.80 ± 2.14 minutes, respectively. All 15 cases were performed without perioperative or long-term complications.
Discussion:
R-LESS in combination with the V-Loc suture and the retroperitoneal tunneling technique can be safely and feasibly performed, especially in sacrocolpopexy and, potentially, in other POP surgeries. With adequate and systematic training, surgeons can acquire the necessary skills to perform this complex surgical procedure.
Related Concept Videos
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Angular Momentum: Single Particle
Single-pass Transmembrane Proteins
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...