Related Experiment Video
Updated: Feb 3, 2026

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
Published on: September 12, 2018
Probing spatial coupling of resistive modes in porous intercalation electrodes through impedance spectroscopy
Aashutosh N Mistry1, Partha P Mukherjee
1School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA. pmukherjee@purdue.edu.
Abstract:
In porous intercalation electrodes, coupled charge and species transport interactions take place at the pore-scale, while often observations are made at the electrode-scale. The physical manifestation of these interactions from pore- to electrode-scale is poorly understood. Moreover, the spatial arrangement of the constituent material phases forming a porous electrode significantly affects the multi-modal electrochemical and transport interplay. In this study, the relation between the electrode specification, resultant porous microstructure, and electrode-scale resistances is delineated based on a virtual deconvolution of the impedance response. Relevant short- and long-range interactions are identified. Without altering the microstructural arrangement, if the electrode thickness is increased, the resistances do not scale linearly with thickness. This dependence is also probed to identify the fundamental origins of thick electrode limitations.
More Related Videos
08:06Author Spotlight: Optimizing Porous Substrate Electroporation Through Micro and Nanochannels for Enhanced Monitoring and Intermediate Stage Characterization
Published on: September 27, 2024
10:51Fabrication and Validation of an Organ-on-chip System with Integrated Electrodes to Directly Quantify Transendothelial Electrical Resistance
Published on: September 26, 2017
Related Concept Videos
NMR Spectroscopy: Spin–Spin Coupling
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Impedance Combination
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...