Comparison of light transmission aggregometry and multiple electrode aggregometry for the evaluation of patients with
Ping Sun1, Eileen McMillan-Ward2, Rajibul Mian3
1Department of Pathology, University of Manitoba, Winnipeg, Manitoba, Canada.
Introduction:
The "gold standard" diagnostic test for assessing in vitro platelet function, light transmission aggregometry (LTA), has limitations to application because of sample requirements. Whole blood or multiple electrode aggregometry (MEA) using the Multiplate® analyzer (Roche Diagnostics) requires smaller blood volumes and less sample manipulation than LTA, making it an attractive clinical testing option. Direct comparisons of MEA with LTA for diagnosis of platelet aggregation abnormalities are few.
Methods:
Ninety-nine patients (66 F/33 M; median age 26 [range 2-86] years), referred for initial laboratory evaluation of mucocutaneous bleeding, had parallel MEA/LTA testing. Concentrations of ADP, arachidonic acid (AA), collagen, and thrombin receptor-activating peptide (TRAP) that produced threshold responses in normal controls were used for testing patients.
Results:
Twenty-nine of the 99 patients (30%) had at least one abnormal agonist response by LTA; 15 of these patients had >1 abnormal agonist response. Thirty-six patients (36%) had at least one abnormal agonist response by MEA; 27 had >1 abnormal agonist response. Sensitivity/specificity of MEA relative to LTA: ADP, 0.70/0.72; AA, 0.71/0.85; collagen, 0.85/0.71; TRAP 0.25/0.84. Negative predictive values (NPVs) for MEA relative to LTA: ADP, 0.90; AA, 0.93; collagen, 0.97; TRAP, 0.96.
Conclusions:
Specific abnormal results of MEA testing did not adequately predict specific abnormalities in LTA testing using threshold agonist concentrations. However, favorable NPVs suggest that MEA may be useful in screening patients for platelet aggregation abnormalities; those with normal MEA results not requiring further diagnostic testing by LTA.
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Standard Electrode Potentials
The Wave Nature of Light
Nursing Process for Patient and Caregiver Teaching III: Evaluation and Documentation
Nurses can use several methods to evaluate patient outcomes. For example, oral questions can assess cognitive learning,...