Related Experiment Video
Updated: Feb 3, 2026

Fecal Microbiota Transplantation via Colonoscopy for Recurrent C. difficile Infection
Published on: December 8, 2014
Diagnostic yield of magnetically assisted capsule endoscopy versus gastroscopy in recurrent and refractory iron
Hey-Long Ching1, Melissa F Hale1, Matthew Kurien1
1Academic Department of Gastroenterology and Hepatology, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Trust, Sheffield, United Kingdom.
Background:
Small-bowel capsule endoscopy is advocated and repeat upper gastrointestinal (GI) endoscopy should be considered for evaluation of recurrent or refractory iron deficiency anemia (IDA). A new device that allows magnetic steering of the capsule around the stomach (magnetically assisted capsule endoscopy [MACE]), followed by passive small-bowel examination might satisfy both requirements in a single procedure.
Methods:
In this prospective cohort study, MACE and esophagogastroduodenoscopy (EGD) were performed in patients with recurrent or refractory IDA. Comparisons of total (upper GI and small bowel) and upper GI diagnostic yields, gastric mucosal visibility, and patient comfort scores were the primary end points.
Results:
49 patients were recruited (median age 64 years; 39 % male). Combined upper and small-bowel examination using the new capsule yielded more pathology than EGD alone (113 vs. 52; P < 0.001). In upper GI examination (proximal to the second part of the duodenum, D2), MACE identified more total lesions than EGD (88 vs. 52; P < 0.001). There was also a difference if only IDA-associated lesions (esophagitis, altered/fresh blood, angioectasia, ulcers, and villous atrophy) were included (20 vs. 10; P = 0.04). Pathology distal to D2 was identified in 17 patients (34.7 %). Median scores (0 - 10 for none - extreme) for pain (0 vs. 2), discomfort (0 vs. 3), and distress (0 vs. 4) were lower for MACE than for EGD (P < 0.001).
Conclusion:
Combined examination of the upper GI tract and small bowel using the MACE capsule detected more pathology than EGD alone in patients with recurrent or refractory IDA. MACE also had a higher diagnostic yield than EGD in the upper GI tract and was better tolerated by patients.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
ATP Yield
The ETC is embedded in the inner mitochondrial membrane and is comprised of four main protein complexes and an ATP synthase. NADH and FADH2 pass electrons to these complexes, which pump protons into the intermembrane space. This distribution of...
Reaction Yield
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...

