Related Experiment Video For Breast cancer
Updated: Feb 3, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Two Different Methods of Region-of-Interest Placement for Differentiation of Benign and Malignant Breast Lesions by
Masoumeh Gity1, Behnaz Moradi, Rasool Arami
1Department of Radiology, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
Abstract:
Purpose: We aimed to investigate the influence of different methods of region-of-interest (ROI) placement on apparent diffusion coefficient (ADC) values in breast tumours and their accuracy in differentiating benign versus malignant tumors in mass and nonmass lesions. Methods and Materials: In this prospective study, 79 patients with 98 breast lesions, from 2015 until 2017, were investigated by 1.5-T breast MRI. Histopathology evaluation were done for all malignant lesions and most of the benign ones. ADC values were measured in normal breast tissue and by two ways of ROI placement in the breast lesions (mass and non-mass): 1- ROI covering the whole lesion, 2- ROI in the highest part (most restricted area) of the lesion in DWI images. The accuracy of these two approaches were compared. Results: The age range was 17-68 years with mean age 43.3 ± 9.9 years. 49% of the lesions were benign and 51% of tumors were malignant. Our results revealed that the measured ADC values in normal breast tissue were higher than breast lesions (P≤0.01). Appropriate cut off determination in non-mass was not valid by both methods, but in mass in the first way was 1.45×10 -³mm²/s and in the most restricted part was 1.16×10-³ mm²/s. ADC values differed significantly between the two ways of ROI placement in mass lesions (P<.001). Most restricted part ADC showed the best diagnostic performance in mass lesions with area under curve 0.88 versus 0.82. Conclusion: ROI placement has significant impact on the meseaured ADC values of breast lesions and ROIs in most restricted parts were more accurate than whole-lesion ROIs. Cut-off values differed significantly based on the methods of measurement.
More Related Videos
Related Concept Videos
Apparent Weight
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
Diffusion
Coefficient of Variation
The coefficient of variation is a practical statistical tool in finance. It allows investors to assess the volatility or...
Coefficient of Correlation
If you suspect a linear relationship between x and y, then r can measure how strong the linear relationship is.
What the VALUE of r tells us:
The value of r is always between –1 and +1: –1 ≤ r ≤ 1.
The size of the correlation r indicates the...
Confidence Coefficient
Apparent Weight and the Earth's Rotation
For an object on the Earth's equator, the net centripetal force that accounts for its rotation is the Earth's pull towards its center, or the weight minus the normal force that prevents it from piercing into the Earth's surface....

