Related Experiment Video
Updated: Feb 3, 2026

Transdermal Measurement of Glomerular Filtration Rate in Mice
Published on: October 21, 2018
An electronic technetium-99m-diethylenetriaminepentaacetic acid glomerular filtration rate spreadsheet with novel
Ran Klein1, Simin Razavi2, Rayhan Memon3
1Department of Medicine, Division of Nuclear Medicine, University of Ottawa.
Background:
Critical clinical decisions are made on the basis of the glomerular filtration rate (GFR) measured using technetium-99m-diethylenetriaminepentaacetic acid (DTPA) administration, followed by multiple time-point plasma sampling. As GFR studies rely on few data points and produce a single result, they are prone to technical errors that may remain inconspicuous.
Objective:
We describe a data analysis worksheet that provides real-time quality control (QC) indicators and evaluate our initial clinical experience.
Methods:
Two hundred and forty-six consecutive GFR studies carried out at our clinics were included. Our protocol used plasma samples at 2, 3, and 4 h after injection of technetium-99m-DTPA. Duplicate plasma samples, background samples, and aliquots of an activity dilution standard were counted. Times were logged for injection and dilution standard preparation, blood sampling, and counting. Data were entered into a custom GFR analysis spreadsheet that flagged QC in real time at warning and error levels, including QC of the expected ratio between dilution standard counts-activity ratio (CARs) measurements, which was newly introduced to our clinic. The prevalence of QC events was analyzed in three phases: baseline, training, and evaluation (n=31, 69, and 146, respectively).
Results:
From the baseline and training phases (n=100), CAR reference values were determined for each of two sites. In the absence of the CAR QC indicator, errors were present in 5/31 (16%) examinations, but with QC indication decreased to 7/146 (5%) (P<0.05), suggesting that the real-time QC information guided the technologists to ensure proper standard preparation and sample handling, as intended. Improvements in other QC measures were also noted, resulting in an overall error rate reduction from 23 to 8%.
Conclusion:
Real-time analysis of redundant information as a component of the GFR worksheet ensures quality results, but training of technologists and interpreting physicians is essential for optimal utilization of these QC indicators.
Related Concept Videos
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...
Quality Assurance
Glomerular Filtration
Components of the Filtration Membrane
The filtration process involves three key layers: the glomerular endothelial cells, the basement membrane, and the podocyte-formed filtration slits.
Glomerular Filtration: Net Filtration Pressure
GBHP, with an average value of 55 mmHg, promotes filtration by pushing water and solutes through the filtration membrane. This is balanced by two opposing forces: CHP, a "back pressure" exerted against the filtration membrane by fluid already in the capsular space and renal...
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration