Oscillometric and Doppler arterial blood pressure measurement in conscious goats
Olga Szaluś-Jordanow1, Michał Czopowicz1, Anna Świerk1
1Department of Small Animal Diseases with Clinic (Szaluś-Jordanow), Laboratory of Veterinary Epidemiology and Economics (Czopowicz, Mickiewicz, Moroz, Kaba), and Department of Pathology and Veterinary Diagnostics (Garncarz, Szpinda), Faculty of Veterinary Medicine, Warsaw University of Life Sciences, Warsaw, Poland; Round-the-clock Veterinary Clinic LEGWET, Legionowo, Poland (Świerk); Institute of Genetics and Animal Breeding, Polish Academy of Science, Magdalenka, Poland (Bagnicka).
Abstract:
The objective of this study was to characterize arterial blood pressure (BP) measurements obtained by using 2 indirect methods, oscillometry and Doppler ultrasonic sphygmomanometry, in conscious goats. Agreement between systolic BP yielded by these 2 methods was then assessed. Sixty female dairy goats aged from 1.5 to 11.8 y (median: 5.5 y) were examined in a standing position with a cuff placed on the tail. All goats had a severe arthritic form of caprine arthritis-encephalitis. Three to 5 repeated measurements of each BP type were averaged for each goat and considered as a final measurement. With oscillometry, systolic blood pressure (O-SBP), diastolic blood pressure, and mean blood pressure, as well as heart rate (HR) were measured, while only systolic blood pressure was measured with Doppler (D-SBP). The O-SBP did not correlate with D-SBP [correlation coefficient (r) = 0.24, P = 0.067]; the mean difference (± standard deviation) was 24.5 ± 26.3 mmHg and limits of agreement were from -27.2 mmHg [95% confidence interval (CI): -39.0, -15.4 mmHg] to 76.1 mmHg (95% CI: 64.3, 87.9 mmHg). No significant linear correlation was found between any BPs and HR (r: -0.10 to 0.22) or age (r: -0.26 to 0.07) of the goats. The study showed that, while BP could be measured in conscious goats using both oscillometry and Doppler ultrasonic sphygmomanometry, the results obtained were so inconsistent that these methods could not be used interchangeably.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)