Assessment of Head Tremor with Accelerometers Versus Gyroscopic Transducers
Rodger J Elble1,2, Helge Hellriegel2, Jan Raethjen2
1Department of Neurology Southern Illinois University School of Medicine Springfield Illinois USA.
Background:
Accelerometers and gyroscopes are used commonly in the assessment of hand tremor, but their validity in the assessment of head tremor has not been studied. We hypothesized that gyroscopy would be superior to accelerometry because head tremor is rotational motion, and gyroscopes record rotational motion, free of gravitational artifact. We also hypothesized a strong logarithmic relationship between 0 to 4-point tremor ratings and the transducer measures of tremor amplitude, similar to those previously reported for hand tremor.
Methods:
Head tremor was recorded for 1 minute in each of the five head positions used in the Essential Tremor Rating Assessment Scale, using a triaxial accelerometer and triaxial gyroscope mounted at the vertex of the head. Mean and maximum 3-second burst displacement tremor and rotation tremor were computed by spectral analysis. The minimum detectable change for the transducers was estimated using the residual mean squared error from repeated-measures analysis of variance.
Results:
Tremor displacement and rotation (T) were logarithmically related to tremor ratings (tremor rating score; TRS): log(T) = α TRS + β, where α ≈ 0.47 for displacement and ≈0.64 for rotation, and β ≈ -1.8 and -1.4. Tremor ratings correlated more strongly with gyroscopy (r = 0.83-0.87) than with accelerometry (r = 0.71-0.75). Minimum detectable change (percent reduction) was approximately 66% of the baseline geometric mean.
Conclusions:
Gyroscopic transducers are superior to accelerometry for assessment of head tremor. Both measures of head tremor are logarithmically related to tremor ratings. The minimum detectable change of the transducer measures is comparable to those previously reported for hand tremor.
Related Concept Videos
Gyroscope
Gyroscope: Precession
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
Transducer Mechanism: Nuclear Receptors
About 48 different soluble family members of nuclear receptors are identified that can be divided into two main classes:
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...