Comparison of the Clinical Performance of Refractive Rotationally Asymmetric Multifocal IOLs with Other Types of
Zequan Xu1, Wenzhe Li2, Lianqun Wu3
1Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, No. 600, Yishan Road, Xuhui District, Shanghai 200233, China.
Objective:
To compare the clinical performance of refractive rotationally asymmetric multifocal intraocular lens (IOLs) with spherical monofocal, accommodating, and bifocal IOLs.
Methods:
A comprehensive literature search of PubMed, EMBASE, Cochrane Controlled Trials Register, and Web of Science up to February 2017 was performed to identify randomized controlled trials (RCT) and comparative cohort studies. Main outcomes were uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), higher-order aberrations (HOAs), MTF, Strehl ratio, and residual sphere and cylinder.
Results:
Mplus provided significantly worse UDVA than spherical monofocal IOLs (WMD: 0.13, P=0.008), but significantly better UIVA than high-add bifocal IOLs (WMD: -0.19, P < 0.00001), spherical monofocal IOLs (WMD: -0.12, P < 0.0001), and accommodating IOLs (WMD: -0.21, P < 0.00001). Mplus provided significantly worse UNVA than high-add bifocal IOLs (WMD: 0.07, P < 0.00001), but significantly better UNVA than spherical monofocal IOLs (WMD: -0.19, P < 0.00001). Mplus resulted in significantly higher HOAs than high-add bifocal IOLs (WMD: 0.38, P < 0.00001) and spherical monofocal IOLs (WMD: 0.51, P=0.0004). Mplus provided a significantly lower MTF cut-off and Strehl ratio than other type of IOLs.
Conclusion:
The Mplus IOLs perform best regarding intermediate visual acuity whereas they lack in distance visual acuity compared to monofocal IOLs and near visual acuity compared to bifocal IOLs. These results may be due to structure of Mplus IOLs resulting in higher-order aberrations.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
04:34Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
Published on: February 17, 2023
Related Concept Videos
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
High-Performance Liquid Chromatography: Types of Detectors
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Asymmetric Lipid Bilayer
The Sense of Self: Reflected Self-Appraisal and Social Comparison