Related Experiment Video
Updated: Feb 3, 2026

10:08
Flow Cytometry Analysis of Tissue Factor Expression in Human Platelets
Published on: November 22, 2024
1.6K
Agreement between blood draw techniques for assessing platelet activation by flow cytometry
Emma L Welch1, Michael G Crooks1, Simon P Hart1
1a Respiratory Research Group, Hull York Medical School, Castle Hill Hospital , Cottingham , UK.
Platelets
|October 27, 2018
Summary
Blood draw technique does not affect platelet activation assays. Using vacuum tubes or syringes, with or without a discard tube, yields comparable results for platelet P-selectin expression and platelet-monocyte complexes.
Area of Science:
- Hematology
- Clinical Pathology
Background:
- Preanalytical variables, particularly blood collection methods, are believed to influence platelet activation assays.
- Accurate assessment of platelet function is crucial for diagnosing and managing various hemostatic and thrombotic disorders.
Purpose of the Study:
- To evaluate the impact of blood collection methods (vacuum tubes vs. manual syringes) on platelet activation.
- To determine the necessity of a discard tube in platelet function testing.
Main Methods:
- Whole blood flow cytometry was used to measure platelet P-selectin expression and platelet-monocyte complexes.
- Blood samples were collected using vacuum tubes and manually aspirated syringes.
- The effect of a discard tube versus a second draw was assessed under basal and stimulated conditions (ADP).
Main Results:
- Bland-Altman analysis showed agreement between vacuum tube and syringe-aspirated samples within a 5% limit.
- No significant difference in platelet activation markers was found between discard tube and second draw samples for both collection methods.
Conclusions:
- Manual syringe aspiration is a viable alternative to vacuum tubes for platelet activation assays.
- The use of a discard tube is not necessary for accurate assessment of platelet activation by flow cytometry.
Related Concept Videos
Flow Cytometry
16.2K
The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
In...
16.2K
Blood Flow
75.9K
Blood is pumped by the heart into the aorta, the largest artery in the body, and then into increasingly smaller arteries, arterioles, and capillaries. The velocity of blood flow decreases with increased cross-sectional blood vessel area. As blood returns to the heart through venules and veins, its velocity increases. The movement of blood is encouraged by smooth muscle in the vessel walls, the movement of skeletal muscle surrounding the vessels, and one-way valves that prevent backflow.
75.9K
Autoregulation of Blood Flow
8.1K
Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
8.1K
Applications of Integration to Find Blood Flow
49
Blood flow through a cylindrical blood vessel can be mathematically described using the principles of laminar flow, a regime in which fluid moves smoothly in parallel layers. In this model, the velocity of the blood is not uniform across the cross-section of the vessel; rather, it varies with the radial distance from the center. The maximum velocity occurs along the central axis, decreasing progressively toward the vessel walls, where it reaches zero due to viscous drag.Approximating Blood...
49
Drawing Free-body Diagrams: Rules
15.8K
The first step in describing and analyzing most phenomena in physics involves the careful drawing of a free-body diagram. Free-body diagrams are useful in analyzing forces acting on an object or system, and are employed extensively in the study and application of Newton's laws of motion. The steps to draw a free-body diagram are listed below:
15.8K
Assessing Blood pressure in the Leg
10.0K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
10.0K

