Objective:
Ventriculoperitoneal (VP) shunt is the most common neurosurgical procedure to treat obstructive and communicating hydrocephalus, but failures are frequent. The most common causes of shunt failure are malpositioning and obstruction of the ventricular catheter by debris or blood clothes. The knowledge of the relationship between ventricular catheter tip position, etiology of hydrocephalus and patient's age with shunt malfunction may be useful to avoid shunt failure.
Patients And Methods:
We retrospectively analyze 89 adult patients affected by obstructive and communicating hydrocephalus operated with Ventriculoperitoneal shunt at our Institute. Patients with evident abdominal shunt malfunction were excluded from this study. Statistical analysis was performed in the group of patients with intracranial catheter malfunction in order to correlate shunt malfunction with the position of the catheter tip in brain ventricles, etiology of hydrocephalus and patient's age.
Results:
Shunt revision was performed in 26 patients out of 89 and cranial catheter malfunction was documented in 11 patients out of 26. Tip position in Monro foramen, lateral ventricles and third ventricle ("good position") had a lower rate of surgical shunt revision compared to septum pellucidum and wall of lateral ventricle ("bad position") p value = 0,049. No statistical significant association was observed between shunt malfunction and etiology of the hydrocephalus or patient's age.
Conclusions:
Ventricular catheter tip position is one the most important factor for shunt function.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:23Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
Published on: February 11, 2017
Related Concept Videos
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Relationship Formation
Ending Relationships
Location and Orientation of the Heart
Relationship Growth
Social Relationships and Well-Being