Fluorescence lifetime shifts of NAD(P)H during apoptosis measured by time-resolved flow cytometry

Faisal Alturkistany1, Kapil Nichani2, Kevin D Houston3,1

  • 1Molecular Biology, New Mexico State University, Las Cruces, New Mexico.

Related Concept Videos

Flow Cytometry01:23

Flow Cytometry

The development of flow cytometry techniques began in 1934 with initial attempts by Andrew Moldavan, a bacteriologist who counted the cells in a flowing capillary system. Moldavan pumped cells through a capillary tube focused under a microscope for visualization. The invention of photometry allowed the measurement of differentially-stained cells, and Louis Kamentsky developed the first multiparameter flow cytometer in 1965 to identify and count the cancer cells in cervical tissue specimens.
In...
16.2K
Apoptosis01:30

Apoptosis

Apoptosis is a combination of two Greek words, 'apo' and 'ptosis,' meaning separation and falling off, respectively. Hippocrates used this word to describe gangrene, which was caused due to bandaging of fractured bones. Apoptosis was distinguished from necrosis in 1970 when John Kerr reported observations of morphological changes occurring during apoptosis. During one experiment, he observed that the disruption of blood supply to the liver tissue resulted in a size...
14.5K
Proton (¹H) NMR: Chemical Shift01:07

Proton (¹H) NMR: Chemical Shift

Organic molecules primarily contain carbon and hydrogen atoms. While all the hydrogen isotopes are NMR-active, protium or hydrogen-1 is the most abundant. It has a significant energy separation between its nuclear spin states due to its large gyromagnetic ratio. As per Boltzmann's distribution, an increase in the energy separation implies a greater excess population of nuclei available for excitation, resulting in a strong NMR absorption signal.
Absorption signals of all the protium nuclei...
3.5K
NMR Spectroscopy: Chemical Shift Overview01:15

NMR Spectroscopy: Chemical Shift Overview

The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
3.3K
Inductive Effects on Chemical Shift: Overview01:27

Inductive Effects on Chemical Shift: Overview

The protons in unsubstituted alkanes are strongly shielded with chemical shifts below 1.8 ppm. Methine, methylene, and methyl protons appear at approximately 1.7, 1.2 and 0.7 ppm, while the proton signal from methane appears at 0.23 ppm. An electronegative substituent, such as chlorine, withdraws the electron density from the protons, increasing their chemical shift. Progressive substitution of the hydrogens in methane by chlorine shifts the proton signals increasingly downfield, to 3.05 ppm in...
2.2K
Gene Flow02:39

Gene Flow

Gene flow is the transfer of genes among populations, resulting from either the dispersal of gametes or from the migration of individuals.
37.8K