Related Experiment Video
Updated: Feb 3, 2026

Palatable Western-style Cafeteria Diet as a Reliable Method for Modeling Diet-induced Obesity in Rodents
Published on: November 1, 2019
A New Method for Studying Licking Behavior Determinants in Rodents: Application to Diet-Induced Obese Mice
Aurélie Dastugue1, Jean-François Merlin1, Guillaume Maquart1
1Physiologie de la Nutrition et Toxicologie (NUTox), UMRU1231 Lipids, Nutrition, Cancer, INSERM Research Group, University of Burgundy Franche-Comté, Dijon, France.
Objective:
An original device for exploring taste-guided reward behavior in rodents using a newly designed computer-controlled liquid delivery system equipped with "lickometers" is described.
Methods:
This octagonal shaped "gustometer" is composed of eight shutters that give random access during a few seconds to eight bottles delivering different liquid stimuli. This original design, which forces the animal to move for access to the drinking source, allows a simultaneous analysis of the licking behavior and motivation to drink. Determination of the sucrose licking behavior in diet-induced obese mice was used to validate this method because nutritional obesity disturbs the sweet taste perception in rodents.
Results:
A rise in sucrose response threshold and a decrease in the motivation to drink sweet solutions were found in mice fed the obesogenic diet. These data were highly reproducible among independent studies and corroborated the existence of functional links between diet-induced obesity and gustation in rodents.
Conclusions:
The FRM-8 gustometer appears to be especially suitable for exploring determinants of behavioral outputs in response to oro-sensory stimuli in the mouse. It also provides substantial information on the taste-reward relationship, useful for better understanding the origin of gustatory efficiency or, conversely, dysfunction, as reported in nutritional obesity.
More Related Videos
Related Concept Videos
Obesity
Induced Electric Fields: Applications
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
What is Behavior?
Drug Dosing: Obese Patients
Dose Size and Dosing Frequency: Determination Methods