Evaluation of a Quantitative Method for Carpal Motion Analysis Using Clinical 3-D and 4-D CT Protocols
Related Experiment Video
Updated: Feb 3, 2026

Analysis of Congenital Heart Defects in Mouse Embryos Using Qualitative and Quantitative Histological Methods
Published on: March 10, 2020
Abstract:
For wrist complaints related to motion, a 2-D radiograph or CT scan of the static wrist may not always be considered diagnostic. 3-D motion imaging, i.e., multiple 3DCT scans in time (4DCT), enables quantifying carpal motion and comparing motion patterns of the affected wrist with those of the healthy contralateral side. The accuracy and precision of the method, however, is limited by noise and motion artifacts. Although, the technique is considered promising in existing literature, the accuracy and precision of carpal motion analysis has never been investigated systematically. In this paper, we introduce and evaluate a semi-automatic segmentation- and registration-based method for 3-D carpal motion analysis. We investigate the accuracy and precision of the method, and its dependency on motion and scan parameters (angular velocity, dose, gantry revolution angle for image reconstruction, and scanner type) using a wrist phantom. During standstill the positioning error was ≤ 0.23 mm and ≤ 0.78°. A partial gantry revolution for 3-D reconstruction introduced image deformation, contributing to a positioning error of approx. 0.8 mm. This error increased with reduced dose, and with increasing angular velocity of the wrist phantom. In cases where the phantom was rotating about an axis parallel to the rotation axis of the gantry, and in a direction opposite to the gantry, the positioning error increased, probably because of the apparent increase in angular velocity with respect to the gantry. Slow carpal motion 4DCT analysis is feasible using a regular CT scanner. A partial gantry revolution angle for 3-D reconstruction may introduce image deformation, which decreases the accuracy of carpal motion analysis. Knowing the positioning error in 4DCT imaging with the proposed method is considered valuable when investigating wrist injury since it enables discrimination of actual motion from apparent motion caused by methodological error.
More Related Videos
09:33An Efficient Method for Quantitative, Single-cell Analysis of Chromatin Modification and Nuclear Architecture in Whole-mount Ovules in Arabidopsis
Published on: June 19, 2014
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Related Concept Videos
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...
Relative Motion Analysis - Acceleration
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...