Related Experiment Video
Updated: Feb 3, 2026

Enumeration of Neural Stem Cells Using Clonal Assays
Published on: October 4, 2016
Leukocyte Cell Population Data for Hematology Analyzer-Based Distinction of Clonal-versus-Non-Clonal Lymphocytosis: A
Pulkit Rastogi1, Prashant Sharma1, Neelam Varma1
11Department of Hematology, Postgraduate Institute of Medical Education and Research, Level 5, Research Block A, Sector 12, Chandigarh, 160012 India.
Automated blood counts revealing lymphocytosis necessitate smear reviews. Even expert morphological evaluation may however, fail to differentiate a benign-versus-malignant etiology without further testing. Automated analyser-derived quantitative data on leukocyte cell populations remain undertested for distinguishing such etiologies. Instrument manufacturers claim that if successful, they may be used to generate software flags that help under-resourced laboratories better triage hemogram specimens requiring further testing. We tested the diagnostic accuracy of volume-conductivity-scatter (VCS) indices together with complete blood count (CBC) parameters in such scenarios. We compared LH780-derived (Beckman Coulter, FL, USA) CBC + VCS parameters from patients with clonal lymphoproliferations (n = 42, including 30 chronic lymphocytic leukemia cases) versus 83 controls with absolute or relative lymphocytosis (derivation cohort). Diagnostic performances of 11 logistic regression equations derived were subsequently evaluated on two specific validation cohorts (n = 130 and n = 1465). Clonal lymphocytoses showed significantly lower hemoglobin and higher leukocyte counts but similar lymphocyte percentages (LY %) vis-à-vis controls. The most significant, albeit overlapping predictor of clonality was the absolute lymphocyte count, LY# (47.8 ± 48.4 × 109/L vs. 2.9 ± 1.4 × 109/L in clonal vs. benign cases). In eleven logistic regression equations constructed using four combinatorial approaches, only the models with LY# (highest sensitivity/specificity of 99.3%/100%) and the lymphocytic VCS parameters alone (highest sensitivity/specificity of 76.2%/90.2%) performed consistently in both validation cohorts. Lymphocytic VCS parameters were moderately successful in distinguishing benign-versus-malignant lymphocytes. Other approaches of CBC-plus-VCS parameters did not sustain their initial excellent performances in the validation cohorts, highlighting a need for careful appraisal and better standardization of automated cellular analysis technologies.
Automated blood counts revealing lymphocytosis necessitate smear reviews. Even expert morphological evaluation may however, fail to differentiate a benign-versus-malignant etiology without further testing. Automated analyser-derived quantitative data on leukocyte cell populations remain undertested for distinguishing such etiologies. Instrument manufacturers claim that if successful, they may be used to generate software flags that help under-resourced laboratories better triage hemogram specimens requiring further testing. We tested the diagnostic accuracy of volume-conductivity-scatter (VCS) indices together with complete blood count (CBC) parameters in such scenarios. We compared LH780-derived (Beckman Coulter, FL, USA) CBC + VCS parameters from patients with clonal lymphoproliferations (n = 42, including 30 chronic lymphocytic leukemia cases) versus 83 controls with absolute or relative lymphocytosis (derivation cohort). Diagnostic performances of 11 logistic regression equations derived were subsequently evaluated on two specific validation cohorts (n = 130 and n = 1465). Clonal lymphocytoses showed significantly lower hemoglobin and higher leukocyte counts but similar lymphocyte percentages (LY %) vis-à-vis controls. The most significant, albeit overlapping predictor of clonality was the absolute lymphocyte count, LY# (47.8 ± 48.4 × 109/L vs. 2.9 ± 1.4 × 109/L in clonal vs. benign cases). In eleven logistic regression equations constructed using four combinatorial approaches, only the models with LY# (highest sensitivity/specificity of 99.3%/100%) and the lymphocytic VCS parameters alone (highest sensitivity/specificity of 76.2%/90.2%) performed consistently in both validation cohorts. Lymphocytic VCS parameters were moderately successful in distinguishing benign-versus-malignant lymphocytes. Other approaches of CBC-plus-VCS parameters did not sustain their initial excellent performances in the validation cohorts, highlighting a need for careful appraisal and better standardization of automated cellular analysis technologies.
Related Concept Videos
T Cell Activation and Clonal Selection
Naive T cells that have not yet encountered an antigen express two primary CD...
Data Collection by Experiments
An example of the experimental method is a public...
Testing a Claim about Mean: Known Population SD
Estimating a population mean requires the samples to be distributed normally. The data should be collected from the randomly selected samples having no sampling bias. The sample size needed to be higher than 30, and most importantly, the population standard deviation should be already known.
In most realistic situations, the population standard deviation is often unknown, but in rare circumstances, when it...
Analysis of Population Pharmacokinetic Data
Testing a Claim about Population Proportion
There are two methods of testing a claim about a population proportion: (1) Using the sample proportion from the data where a binomial distribution is approximated to the normal distribution and (2) Using the binomial probabilities calculated from the data.
The first method uses normal distribution as an approximation to the binomial distribution. The requirements are as follows: sample size is large...
Testing a Claim about Mean: Unknown Population SD
Estimating a population mean requires the samples to be approximately normally distributed. The data should be collected from the randomly selected samples having no sampling bias. There is no specific requirement for sample size. But if the sample size is less than 30, and we don't know the population standard deviation, a different approach is used;...