Zero contrast retrograde chronic total occlusions percutaneous coronary intervention: a case series

Raja Hatem1,2,3, Matthew T Finn1,2, Robert F Riley4

  • 1Columbia University, 161 Fort Washington Avenue, 6th Floor, New York, NY, USA.

Insights

Zero contrast percutaneous coronary intervention (PCI) successfully treated chronic total occlusions in patients with advanced chronic kidney disease (CKD). This approach avoids contrast dye, protecting kidney function in high-risk patients.

Area of Science:

  • Cardiology
  • Nephrology
  • Interventional Cardiology

Background:

  • Percutaneous coronary intervention (PCI) in advanced chronic kidney disease (CKD) risks contrast-induced nephropathy and CKD progression.
  • Chronic total occlusions (CTO) PCI is vital for refractory angina and ischemic heart failure.
  • Minimal or zero contrast PCI strategies using intravascular imaging and physiology are emerging.

Observation:

  • Two patients with severe CKD (eGFR ≤15 mL/min) and angina underwent diagnostic angiography with minimal contrast.
  • Following a recovery period, both patients successfully received retrograde zero contrast CTO-PCI.
  • Intravascular ultrasound imaging was utilized as an adjunctive tool during the procedures.

Findings:

  • This report details the first two successful retrograde zero contrast CTO-PCI procedures.
  • Successful stent implantation was achieved without contrast administration.
  • The interventions resolved ischemia in both patients.

Implications:

  • Zero contrast PCI is a feasible technique for treating obstructive coronary disease in severe CKD patients.
  • This approach can prevent worsening renal function in high-risk populations.
  • Further research into zero contrast PCI techniques is warranted for broader application.
Abstract

Related Concept Videos

Nursing Interventions I: Taxonomy of Nursing Interventions01:03

Nursing Interventions I: Taxonomy of Nursing Interventions

Nursing interventions are chosen as part of the planning process to achieve patient outcomes. Once nursing diagnoses are determined, the goals and outcomes are specified, then the nursing interventions are selected and individualized according to the patient's situation.
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
3.9K
Nursing Interventions II: Selecting and Classifying the Nursing Interventions01:29

Nursing Interventions II: Selecting and Classifying the Nursing Interventions

Creating and executing a nursing diagnosis helps nurses plan care and guide patient, family, and community interventions. They are developed based on a patient's physical evaluation and support measuring the outcomes. It is not recommended to select random interventions throughout the planning process. Instead, consider the following six essential factors when choosing interventions:
3.3K
Resistors In Series01:10

Resistors In Series

A resistor is an ohmic device that limits the flow of charge in a circuit. Most circuits have more than one resistor. If several resistors are connected together and connected to a battery, the current supplied by the battery depends on the equivalent resistance of the circuit. The equivalent resistance of a combination of resistors depends on both their individual values and how they are connected. The simplest combination of resistors is the series combination. 
In a series circuit, the...
6.4K
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
13.5K
Series Resonance01:17

Series Resonance

The RLC circuit impedance is defined as the ratio of the supply voltage to the circuit current. Resonance in such a circuit occurs when the imaginary part of this impedance equals zero. This specific condition means that the inductive reactance is exactly equal to the capacitive reactance. The frequency at which this happens is known as the resonant frequency. Mathematically, the resonant frequency is inversely proportional to the square root of the product of the inductance (L) and capacitance...
809
Coronary Circulation01:21

Coronary Circulation

The heart, an organ critical to survival, gets nourishment not from the blood it pumps but from a separate circulation system known as coronary circulation. This is the shortest circulation in the body and is responsible for supplying the heart with the nutrients it needs to function effectively.
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
7.3K