Related Experiment Video
Updated: Feb 3, 2026

Enucleation of the Prostate for the Treatment of Benign Prostatic Hyperplasia Using a 980 nm Diode Laser
Published on: May 5, 2020
Comparison of < 100 cc prostates and > 100 cc prostates undergoing aquablation for benign prostatic hyperplasia
N Bhojani1, D-D Nguyen2, R P Kaufman3
1Division of Urology, University of Montreal Hospital Center, Université de Montréal, Montreal, Canada. naeem.bhojani@gmail.com.
Introduction:
Surgical options for benign prostatic hyperplasia (BPH) become limited when treating large prostates due to steep learning curves and less effective treatment. Aquablation (AquaBeam System, PROCEPT BioRobotics, Inc., USA) could remedy this. We compare the effectiveness of Aquablation in large prostates between 80 cc and 100 cc and very large prostates > 100 cc.
Methods:
WATER II (NCT03123250) is a prospective, multicenter, international clinical trial of Aquablation for the surgical treatment of LUTS/BPH in men of age 45-80 years with prostates between 80 cc and 150 cc. Aquablation was performed using the AquaBeam System. The reported analysis compares the subgroup of patients with a baseline prostate size of < 100 cc versus those with a prostate size of > 100 cc. Students' t test was used for continuous variables and Fisher's test for ordinal/binary variables.
Results:
Of 114 screened patients, 101 meeting eligibility criteria were enrolled at 13 US and 3 Canadian sites between September and December 2017. Mean operative time was 31.2 ± 8 min in the < 100 cc subgroup and 41.7 ± 14.9 min in the > 100 cc subgroup. The average length of stay following the procedure for the < 100 cc subgroup was 1.5 ± 0.7 days versus 1.7 ± 1.1 days for the > 100 cc subgroup. Mean changes in International Prostate Symptom Score (IPSS), IPSS quality of life, and IPSS voiding and storage subscores were substantial, occurring soon after treatment and averaging (at 3 months) 16.5, 2.8, 10.6, and 5.8 points, respectively (all p < 0.0001).
Conclusion:
Aquablation clinically normalizes outcomes between patients of the < 100 cc and > 100 cc prostate cohorts. It is safe and effective in patients with large prostate glands (> 100 cc) with a smoother learning curve.
More Related Videos
06:04Surgical Treatment for Benign Prostatic Hyperplasia: Holmium Laser Enucleation of the Prostate HoLEP.
Published on: March 6, 2018
08:38Renal Capsule Xenografting and Subcutaneous Pellet Implantation for the Evaluation of Prostate Carcinogenesis and Benign Prostatic Hyperplasia
Published on: August 28, 2013
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits
Molecular Comparison of Gases, Liquids, and Solids