Iron-Containing Abdominal Pathologies: Exploiting Magnetic Susceptibility Artifact on Dual-Echo Gradient-Echo

Aaron J Thomas, Ajaykumar C Morani1, Peter S Liu2

  • 1Department of Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX.

Summary

Abnormal abdominal iron deposition causes decreased MRI signal on longer echo times due to T2* effects. This review illustrates iron-containing pathologies and their distributions, discussing MRI physics.

Related Concept Videos

Echo01:06

Echo

The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
959
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.3K
Magnetic Susceptibility and Permeability01:31

Magnetic Susceptibility and Permeability

In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
2.4K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
280
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Nuclear Magnetic Resonance (NMR): Overview01:07

Nuclear Magnetic Resonance (NMR): Overview

Nuclear magnetic resonance (NMR) is a phenomenon exhibited by certain nuclei that can absorb characteristic radio frequency radiation under certain conditions. NMR has been extensively applied in molecular spectroscopy and medical diagnostic imaging. In both these applications, the molecule or subject under study is placed in a magnetic field and irradiated with radio frequency energy.
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
6.9K