A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
Use of a Safety Clamp When Performing Arthroscopic Knot Tying Preserves the Suture When It Is Placed Under Excessive
Abstract:
The purpose of this study was to compare the location of the suture breakage between tying by hand vs with a safety clamp, needle driver. FiberWire No. 2 and 2-0 (Arthrex, Naples, Florida) were fastened onto the hook attachment of the digital force gauge. Sutures were placed under excessive strain using a hand tying technique vs a safety clamp, or instrument tying. Peak forces at which the sutures failed under tension along with locations of the suture breakage, measured from the site of the knot, were recorded. For FiberWire No. 2, the mean load to failure was 142.60±2.33 N for hand tying and 78.79±1.97 N for the safety clamp (P<.0001). For FiberWire 2-0, the mean load to failure was 62.98±4.90 N for hand tying and 34.43±2.46 N for the safety clamp (P<.0001). For FiberWire No. 2, the mean location of suture breakage was 0 cm, at the site of the knot, for hand tying and at the clamping point (10.45±0.34 cm from the knot) for the safety clamp (P<.0001). For FiberWire 2-0, the mean location of suture breakage was 0 cm, at the site of the knot, for hand tying and at the clamping point (10.47±0.22 cm from the knot) for the safety clamp (P<.0001). Use of a safety clamp while mastering arthroscopic suture technique preserves the suture knot when placed under excessive tension. [Orthopedics. 2019; 42(1):e25-e28.].
More Related Videos
05:21Laparoscopic Extracorporeal Knot-Tying for Uterine Vessel Occlusion during Hysterectomy with Cervical Cerclage in Large Uteri
Published on: September 12, 2025
07:22Arthroscopic Management of Massive Irreparable Rotator Cuff Tears: Whole Rotator Cable Reconstruction Using Proximal Biceps Tendon Autograft
Published on: June 6, 2025
Related Concept Videos
Tension
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Survey Safety
Excess Pressure Inside a Drop and a Bubble
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Surface Tension of Fluid
Surface tension varies...