Related Experiment Video
Updated: Feb 3, 2026

Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
Optical Fibre-Based Pulse Oximetry Sensor with Contact Force Detection.
Chong Liu1, Ricardo Correia2, Hattan Khaled Ballaji3
1Optics and Photonics Group, Faculty of Engineering, University Park, Nottingham NG7 2RD, UK. chong.liu@nottingham.ac.uk.
This study introduces a novel optical sensor probe that measures blood oxygen saturation (SpO₂) and contact pressure simultaneously. This innovation enhances the accuracy of SpO₂ readings, particularly for wearable technologies.
Area of Science:
- Biomedical Engineering
- Optical Sensing
- Wearable Technology
Background:
- Contact pressure significantly impacts blood oxygen saturation (SpO₂) measurements.
- Existing pulse oximetry methods can be affected by pressure artifacts, reducing accuracy.
Purpose of the Study:
- To develop and validate a novel optical sensor probe integrating SpO₂ monitoring with contact pressure sensing.
- To improve the reliability and accuracy of SpO₂ measurements in applications sensitive to pressure variations.
Main Methods:
- The sensor combines plastic optical fibers (POF) for pulse oximetry with a fiber Bragg grating (FBG) for contact pressure measurement.
- A biocompatible epoxy patch houses the optical fibers, reducing motion artifacts and transducing pressure into strain for the FBG.
- FBG sensors, alongside a reference FBG, were used to ensure temperature-independent and reliable pressure readings.
Main Results:
- The combined sensor demonstrated low hysteresis and temperature immunity.
- Measurements on ten volunteers showed that contact forces between 5 to 15 kPa resulted in SpO₂ errors of less than 2%.
- Perfusion and skewness indices were used to assess photoplethysmogram (PPG) quality.
Conclusions:
- The novel combined optical sensor probe significantly improves the reliability of reflectance oximetry.
- This technology holds potential for enhancing wearable devices and optimizing garment integration for accurate SpO₂ monitoring.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Contact-dependent Signaling
Gap Junctions