Long-Term Safety of Intraperitoneal Radio Transmitter Implants in Brown Bears (Ursus arctos)
Jon M Arnemo1,2, Bjørnar Ytrehus3,4, Knut Madslien4
1Department of Forestry and Wildlife Management, Inland Norway University of Applied Sciences, Koppang, Norway.
Abstract:
Intraperitoneal radio transmitters have been widely used in free-ranging wild mammals, but there are no long-term studies on their biocompatibility or technical stability within the abdominal cavity of animals. Possible negative health effects may bias results from ecological studies on instrumented animals and raise concerns over animal welfare issues. The aim of this study was to evaluate the long-term technical stability and pathological effects of Telonics intraperitoneal very high frequency (VHF) radio transmitters in brown bears (Ursus arctos). We instrumented 305 individual bears with intraperitoneal VHF radio transmitters during a 19-year period. We surgically removed devices that had been in bears for 1-9 years and collected transmitters from animals that died 1-13 years after implantation. We took biopsies for histopathology from tissue encapsulating implants in live bears. Retrieved transmitters underwent a technical inspection. Of the 125 transmitters removed from live bears, 66 were free-floating in the peritoneal cavity [a mean (SD) of 3.8 (1.5) years after implantation], whereas 59 were encapsulated in the greater omentum [4.0 (1.8) years after implantation]. Histopathology of biopsies of the 1-15 mm thick capsules in 33 individuals showed that it consisted of organized layers of connective tissue. In one third of the bears, the inner part of the capsule was characterized by a foreign body reaction. We inspected 68 implants that had been in bears for 3.9 (2.4) years. The batteries had short-circuited four (5.9%) of these devices. This resulted in the death of two animals 10 and 13 years after implantation. In two other bears that underwent surgery, we found the short-circuited devices to be fully encapsulated within the peritoneal cavity 5 and 6 years after implantation. A significant proportion of the other 64 inspected implants showed serious technical problems, such as corrosion of metal parts or the batteries (50%), detachment of the end cap (11.8%), and erosion (7.4%) or melting (5.9%) of the wax coating. We conclude that the wax coating of the transmitters was not biocompatible, that the technical quality of the devices was poor, and that these implants should not be used in brown bears.
More Related Videos
09:11Implantation of Radiotelemetry Transmitters Yielding Data on ECG, Heart Rate, Core Body Temperature and Activity in Free-moving Laboratory Mice
Published on: November 21, 2011
08:30Subdural Soft Electrocorticography ECoG Array Implantation and Long-Term Cortical Recording in Minipigs
Published on: March 31, 2023
Related Concept Videos
Survey Safety
Collar Bearings
Bearing Stress
Due to the intricacy of these microforces, an average value, known as bearing stress, is often used by...
Azimuths and Bearings
Pivot Bearings
A pivot bearing is a specialized type of bearing designed to support axial loads on a rotating shaft. The bearing surface, or the pivot, is positioned at the end of a shaft to support the axial thrust. The pivot may...
Journal Bearings
To better understand the concept of journal bearings, consider a rope winch with dry or...