Implementation and evaluation of respiratory gating in small animal radiotherapy
Related Experiment Video
Updated: Feb 3, 2026

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
A-M Frelin1,2, V Beaudouin3, C Le Deroff1
1Grand Accélérateur National d'Ions Lourds (GANIL), CEA/DRF-CNRS/IN2P3, Boulevard Henri Becquerel, 14076 Caen, France.
Abstract:
Major advance was done in preclinical radiotherapy thanks to the development of image guided micro-irradiator. Nevertheless, some applications still can benefit of improvements, such as the irradiation of mobile tumors. This preclinical radiotherapy case presents increased difficulties compared to clinical practice because of the waveform of small animals breathing cycle, its frequency and amplitude. To answer this issue, we developed a specific beam shutter and implemented respiratory gating on the X-RAD 225Cx preclinical irradiator. In the first step of this study, the shutter was accurately characterized. Opening and closing speed of 1.28 and 0.33 mm ms-1 were respectively measured, and a transmission of 0.7% of the beam was measured with the shutter fully closed. Beam-on times were also determined for various gating parameters and highlighted a difference of 57 ms between the beam delivery duration and the gate width. This discrepancy was compensated during the respiratory monitoring adjustment. In a second step, a respiratory protocol was evaluated with two vertical beams of 2.5 and 5 mm diameters, for motion amplitudes ranging from 0.5 to 4 mm. This evaluation demonstrated the effectiveness of our set up to perform motion compensation for amplitude as small as 0.5 mm despite a dose gradient of 1.47 cGy mm-1 observed with the 5 mm irradiation field, due to the shutter opening and closing durations. We also investigated the efficiency of a scintillating fiber dosimeter, adapted to small beams and providing real-time dose rate measurements. This detector showed very good performances to detect motion in small irradiation fields and would be very suitable to monitor the number of delivered gates until the planned delivered dose is achieved. This study presented a new respiratory gating set up and showed that very efficient motion compensation could be achieved in small animal radiotherapy.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Related Concept Videos
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
Animal Mitochondrial Genetics
Underflow Gates
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Anatomy of Respiratory System II: Lower Respiratory Tract
The Larynx
It is located between the pharynx and the trachea, acts as a passageway for air, and hosts several critical structures, such as the epiglottis, vocal cords, and glottis. The epiglottis acts as a gateway, guiding food to the...
The Respiratory System