Related Experiment Video
Updated: Feb 3, 2026

In Situ Surface Temperature Measurement in a Conveyor Belt Furnace via Inline Infrared Thermography
Published on: May 30, 2020
Robust sensing suite for measuring temporal dynamics of surface temperature in sewers
Karthick Thiyagarajan1, Sarath Kodagoda2, Ravindra Ranasinghe2
1Centre for Autonomous Systems, University of Technology Sydney, Sydney, NSW, 2007, Australia. Karthick.Thiyagarajan@uts.edu.au.
Abstract:
Sewerage systems are paramount underground infrastructure assets for any nation. In most cities, they are old and have been exposed to significant microbial induced corrosion. It is a serious global problem as they pose threats to public health and economic repercussions to water utilities. For managing sewer assets efficaciously, it is vital to predict the rate of corrosion. Predictive models of sewer corrosion incorporate concrete surface temperature measurements as an observation. However, currently, it has not been fully utilized due to unavailability of a proven sensor. This study reports the feasibility of infrared radiometer for measuring the surface temperature dynamics in the aggressive sewer conditions. The infrared sensor was comprehensively evaluated in the laboratory at different environmental conditions. Then, the sensor suite was deployed in a Sydney based sewer for three months to perform continuous measurements of surface temperature variations. The field study revealed the suitability of the developed sensor suite for non-contact surface temperature measurements in hostile sewer conditions. Further, the accuracy of the sensor measurements was improved by calibrating the sensor with emissivity coefficient of the sewer concrete. Overall, this study will ameliorate the present sewer corrosion monitoring capabilities by providing new data to models predicting sewer corrosion.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Introduction to Special Senses
Tactile and Chemical Senses

