Related Experiment Video
Updated: Feb 3, 2026

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Cardiac output changes from prior to pregnancy to post partum using two non-invasive techniques
Giulia Masini1, Lin F Foo1, Jérôme Cornette2
1Department of Surgery and Cancer, Imperial College London, London, UK.
Objectives:
We aimed to describe cardiac output (CO) trend from prepregnancy to post partum using an inert gas rebreathing (IGR) device and compare these measurements with those obtained by a pulse waveform analysis (PWA) technique, both cross-sectionally and longitudinally.
Methods:
Non-smoking healthy women, aged 18-44 years, with body mass index <35 were included in this prospective observational study. CO measurements were collected at different time points (prepregnancy, at four different gestational epochs and post partum) using IGR and PWA. A linear mixed model analysis tested whether the longitudinal change in CO differed between the techniques. Bland-Altman analysis and intraclass correlation coefficient (ICC) were used for cross-sectional and a four-quadrant plot for longitudinal comparisons.
Results:
Of the 413 participants, 69 had a complete longitudinal assessment throughout pregnancy. In this latter cohort, the maximum CO rise was seen at 15.2 weeks with IGR (+17.5% from prepregnancy) and at 10.4 weeks with PWA (+7.7% from prepregnancy). Trends differed significantly (p=0.0093). Cross-sectional analysis was performed in the whole population of 413 women: the mean CO was 6.14 L/min and 6.38 L/min for PWA and IGR, respectively, the percentage of error was 46% and the ICC was 0.348, with similar results at all separate time points. Longitudinal concordance was 64%.
Conclusions:
Despite differences between devices, the maximum CO rise in healthy pregnancies is more modest and earlier than previously reported. The two methods of CO measurement do not agree closely and cannot be used interchangeably. Technique-specific reference ranges are needed before they can be applied in research and clinical settings.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Regulation of Water Output

