Related Experiment Video
Updated: Feb 3, 2026

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Multiparametric ultrasound evaluation with CEUS and shear wave elastography for carotid plaque risk stratification
N Di Leo1, L Venturini2, V de Soccio3
1Dipartimento di Scienze Radiologiche, Oncologiche e Anatomopatologiche, Policlinico Umberto I Roma, Viale del Policlinico 155, 00161, Rome, RM, Italy. nicola.dileo130287@gmail.com.
Purpose:
To assess the diagnostic effectiveness of Multiparametric ultrasound (MPUS), which includes color Doppler ultrasound (CDUS), CEUS and Shear wave elastography (SWE), for evaluating carotid plaque as compared with CT-angiography (CTA) and histology.
Materials And Methods:
Forty-three consecutive patients scheduled to undergo carotid endarterectomy underwent MPUS. Then, after periods ranging from 2 days to 2 weeks, all underwent CTA. Each plaque was classified by means of dedicated scores for CEUS and SWE as compared with CTA features. At surgery, each plaque was removed in a single fragment to facilitate histological analysis, which evaluated 4 features: extension of the lipid core, thickness of the fibrous cap, inflammatory infiltrate (CD68 + and CD3 + markers) and the presence of intraplaque microvessels. For the CEUS, SWE and CTA, the following values for identifying plaque vulnerability were evaluated: sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV) and Area under the curve (AUC). Cohen's kappa was used to evaluate the concordance between measurements in the different imaging methods. A p < 0.05 was considered statistically significant.
Results:
At histology, 31 out of 43 plaques were identified as vulnerable because of the presence of at least one of the following criteria: fibrous cap < 200 μm, lipid core, intraplaque hemorrhage, inflammatory infiltrate or intraplaque neovascularization. CTA showed a sensitivity of 87.1%, a specificity of 100%, a PPV of 100%, an NPV of 75% and an AUC of 93.5%. SWE showed a sensitivity of 87.1%, a specificity of 66.7%, a PPV of 87.1%, an NPV of 66.7% and an AUC of 76.9%. CEUS showed a sensitivity of 87.1%, a specificity of 58.3%, a PPV of 84.4%, an NPV of 63.6% and an AUC of 72.7%.
Conclusions:
Multiparametric ultrasound is an effective modality to obtain comprehensive information on carotid plaques. Further studies are needed to determine whether it can be considered a diagnostic standard.
Related Concept Videos
The Wave Nature of Light
Shear Diagram
First, a free-body diagram of the beam is drawn, representing all the external forces and internal reactions acting on the beam. One can calculate the reaction forces at each support by employing the equilibrium equations of force and moment. The vertical component...
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Shearing Strain
Relative Risk
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...