Related Experiment Video For Contrast-enhanced ultrasonography
Updated: Feb 3, 2026

Combined Intravital Microscopy and Contrast-enhanced Ultrasonography of the Mouse Hindlimb to Study Insulin-induced Vasodilation and Muscle Perfusion
Published on: March 20, 2017
[Perfusion Imaging of Ovarian Masses with Contrast-enhanced Ultrasonography]
Fan Yang1,2, Tai-Zhu Yang1,2, Tian Tian1,2
1Department of Diagnostic Ultrasound, West China Second University Hospital, Sichuan University, Chengdu 610041, China.
Objective:
To determine the perfusion features of ovarian masses and their diagnostic value.
Methods:
Contrast-enhanced ultrasonography (CEUS) of 81 ovarian masses were confirmed by surgical pathology. Time-intensity curves of perfusion were obtained for the interest areas of ovarian mass. CEUS perfusion parameters were estimated, including rise time (RT), time to peak (TTP), peak intensity (PI), time from peak to one half (TTH) and area under the curve (AUC). Repeatability of those parameters was tested. Differences in the perfusion parameters were tested between benign and malignant masses, between tumor and non-tumor masses, between different differentiated and stages of ovarian cancers, between cancers with and without lymph-node metastases, and between primary and metastatic cancers. Receive operating characteristic (ROC) curve analyses were performed to determine the cutoff values of perfusion parameters for discriminating cancer from benign ovarian masses.
Results:
Good intra-observer repeatability was reached in the five perfusion parameter measurements. PI, TTH and AUC increased significantly in ovarian cancer and tumor compared with benign and non-tumor masses (P<0.05) . PI, TTH and AUC were effective parameters in diagnosing ovarian cancer. AUC had the highest diagnostic effectiveness, with a sensitivity of 87.3% and a specificity of 80.8% at the cutoff value of 877 dB?s. There were no differences in the parameters between different differentiated and stages of ovarian cancers, between cancers with and without lymph-node metastases, and between the primary and metastatic cancers.
Conclusion:
Malignant ovarian cancer has higher PI, TTH and AUC values in CEUS. AUC has certain value in diagnosing ovarian cancer.
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Atomic Mass
Ovarian Cycle