Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Movement Joints in Buildings01:27

Movement Joints in Buildings

348
Movement joints in buildings are essential design elements that accommodate inevitable motions caused by various factors such as temperature changes, moisture content variations, and structural deflections. These motions, if not considered in design and construction, can lead to unsightly or dangerous damage. Movement joints are incorporated in different forms to manage these stresses and allow materials to move without causing distress.
The simplest type of movement joints, working joints, are...
348
Types of Building Stone01:30

Types of Building Stone

446
Building stones, essential materials for construction, are extracted from natural rock deposits and processed into specific forms and dimensions suitable for various building applications. These stones are broadly classified into three types based on their geological formation: igneous, sedimentary, and metamorphic.
Igneous rocks are formed from the solidification of magma or lava. An example is granite, known for its durability and resistance to weathering, making it ideal for parts of...
446
Types of Building Separation Joints01:23

Types of Building Separation Joints

607
Building separation joints divide large or complex building structures into smaller, discrete units that can move independently. These joints are categorized into three types: volume-change joints, settlement joints, and seismic separation joints.
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
607
Design Example: Sustainability in Concrete Building01:26

Design Example: Sustainability in Concrete Building

417
As the construction industry moves towards more eco-friendly practices, concrete's adaptability and its ability to incorporate sustainable features make it a key material in the drive towards greener building solutions.
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
417
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

1.2K
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
1.2K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

883
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
883

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Sex and Age Affect Progression to Total Knee Arthroplasty After Cartilage Surgery: A UK Biobank Cohort Study.

Cartilage·2026
Same author

Current Advances and Controversies in Spine Imaging.

Seminars in musculoskeletal radiology·2026
Same author

GRAPPA 2025 Annual Meeting: Advances in Psoriatic Disease Research From Pilot Grant Awardees.

The Journal of rheumatology·2026
Same author

Pitfalls in Imaging of Spinal Infection.

Seminars in musculoskeletal radiology·2026
Same author

Ten year follow-up of a randomized trial of autologous chondrocyte implantation versus alternative forms of surgical cartilage management in the knee.

Osteoarthritis and cartilage·2026
Same author

A Biomechanical Study Comparing Patient-Specific Plates with Standard Plates for Distal Radius Malunion Correction.

The journal of hand surgery Asian-Pacific volume·2025

Related Experiment Video

Updated: Feb 3, 2026

Author Spotlight: Developing Cost-Effective and Durable Ultrasound-Guided 3D-Printed Nerve Block Trainers
08:03

Author Spotlight: Developing Cost-Effective and Durable Ultrasound-Guided 3D-Printed Nerve Block Trainers

Published on: February 9, 2024

3.3K

Building an orthopaedic CT phantom for under £50.

Bernhard Tins1, Jan Herman Kuiper2,3

  • 11 Department of Radiology, Robert Jones and Agnes Hunt Orthopaedic Hospital , Oswestry , UK.

The British Journal of Radiology
|November 1, 2018
PubMed
Summary

Researchers developed a low-cost, portable, and durable phantom to test how well CT scanners visualize bone lesions near metal implants. This tool helps hospitals compare scanner performance during equipment purchasing and optimize clinical imaging protocols.

Keywords:
metal artifactsdiagnostic radiologyquality assuranceimaging protocols

Frequently Asked Questions

More Related Videos

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
06:33

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement

Published on: July 29, 2013

11.7K
Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging
04:54

Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging

Published on: June 16, 2023

3.8K

Related Experiment Videos

Last Updated: Feb 3, 2026

Author Spotlight: Developing Cost-Effective and Durable Ultrasound-Guided 3D-Printed Nerve Block Trainers
08:03

Author Spotlight: Developing Cost-Effective and Durable Ultrasound-Guided 3D-Printed Nerve Block Trainers

Published on: February 9, 2024

3.3K
Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
06:33

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement

Published on: July 29, 2013

11.7K
Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging
04:54

Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging

Published on: June 16, 2023

3.8K

Area of Science:

  • Orthopaedic imaging research within medical physics
  • Diagnostic radiology instrumentation and CT phantom development

Background:

No standardized, affordable tool currently exists to evaluate how different computed tomography systems manage metal-induced image distortion near orthopedic hardware. Clinicians often struggle to compare scanner capabilities when assessing bone health around implants. Prior research has shown that metal artifacts significantly degrade image quality, obscuring critical diagnostic details. That uncertainty drove the need for a portable, cost-effective testing device. Existing commercial phantoms are often expensive, bulky, and difficult to transport between clinical sites. This gap motivated the creation of a DIY alternative using readily available materials. Previous studies focused on complex, high-cost phantoms that do not reflect the practical needs of procurement teams. No prior work had resolved the challenge of creating a stable, reproducible, and inexpensive testing model for orthopedic hardware.

Purpose Of The Study:

The primary aim of this study was to develop an affordable and portable testing device for evaluating computed tomography scanner performance. Researchers sought to address the lack of accessible tools for assessing metal artifact reduction in orthopedic contexts. The project focused on creating a model that is easy to build using common materials. The team intended to provide a solution that is stable over time and resistant to biological decay. This effort was motivated by the need to compare scanner capabilities during the procurement process. The study also aimed to support quality assurance and the optimization of scan parameters in clinical settings. By creating a standardized phantom, the authors hoped to facilitate objective assessments of imaging protocols. The research addresses the practical challenges of transporting and maintaining testing equipment in clinical environments.

Main Methods:

The design approach utilized spare knee replacement components to simulate anatomical structures within a controlled environment. Investigators integrated wall filler and polystyrene to represent surrounding bone tissue. To simulate bone lesions, the team embedded various plastic strips and cylinders between the metal implant and the synthetic bone. The entire assembly was secured inside a watertight acrylic box using epoxy resin for structural integrity. Reviewing the assembly process, the team completed fabrication in under three hours of total labor. The strategy prioritized portability, allowing the box to be filled with water only when needed for testing. This method ensures consistent attenuation across different clinical sites. The researchers validated the stability of the device by ensuring it remained unaffected by the decay processes typical of biological materials.

Main Results:

The strongest finding indicates that a functional testing device can be produced for a total cost of less than fifty pounds. The manufacturing process requires fewer than three hours of total time. The resulting model successfully mimics a femur and tibia with a total knee replacement. It provides a stable, reproducible environment for evaluating metal artifact reduction. The phantom remains easily transportable when empty, as the water-filling step occurs only at the destination. The researchers confirmed that the device effectively allows for the visualization of artificial bone lesions. It supports direct comparisons of technical factors and software performance between different scanners. The study highlights that common DIY materials are sufficient to create a robust tool for diagnostic quality assurance.

Conclusions:

The authors demonstrate that a functional testing device can be assembled using minimal resources and common hardware store supplies. This model provides an objective way to evaluate scanner performance regarding metal artifact reduction. It serves as a practical tool for comparing different imaging systems during the procurement process. The device remains stable over time, avoiding the degradation issues common with biological tissue models. Researchers propose that this phantom facilitates the optimization of scan parameters for clinical practice. It allows for consistent assessment of bone lesion visibility near metallic components. The study confirms that building such a tool requires less than three hours of labor. These findings suggest that low-cost solutions can effectively support quality assurance in diagnostic radiology.

The researchers propose that the phantom allows for objective comparisons of scanner performance. By using standardized components, it enables direct assessment of how different systems handle metal artifacts when visualizing bone lesions near implants.

The device incorporates spare knee replacement parts, wall filler, and polystyrene to mimic anatomical structures. Plastic strips and cylinders are embedded within the assembly to serve as artificial bone lesions for testing purposes.

A watertight acrylic box is necessary to house the assembly. Filling this container with water on-site ensures consistent attenuation, which is vital for achieving reproducible imaging results across different testing environments.

The phantom serves as a physical model for quality assurance and protocol optimization. It acts as a standardized test object that allows users to assess how software and hardware settings influence image quality.

The researchers measured the total manufacturing time to be under three hours. This duration was spread across several days to allow for the proper setting of materials like epoxy resin and wall filler.

The authors suggest that this tool supports the procurement process by providing a low-cost, portable method for comparing scanner capabilities. It enables facilities to make informed decisions without relying on expensive, proprietary testing equipment.