Related Experiment Video
Updated: Feb 3, 2026

A Simple and Low-cost Assay for Measuring Ambulation in Mouse Models of Muscular Dystrophy
Published on: December 29, 2017
Is Activity Tracker-Measured Ambulation an Accurate and Reliable Determinant of Postoperative Quality of Recovery? A
Faraj Massouh1, Rachel Martin1,2, Bokman Chan1,2
1From the Department of Anesthesia, University of Toronto, Toronto, Ontario, Canada.
Background:
Quality of recovery (QOR) instruments measure patients' ability to return to baseline health status after surgery. Whether, and the extent to which, postoperative ambulation contributes to QOR is unclear, in part due to the lack of valid tools to measure ambulation in clinical settings. This cohort study of the cesarean delivery surgical model examines the accuracy and reliability of activity trackers in quantifying early postoperative ambulation and investigates the correlation between ambulation and QOR.
Methods:
A prospective cohort of 200 parturients undergoing cesarean delivery between July 2015 and June 2017 was fitted with wrist-worn activity trackers immediately postpartum. The trackers were collected 24 hours later, along with QOR assessments (QoR-15 scale). The relationship between QOR and various covariates, including ambulation, was explored using multivariable linear regression and Spearman correlation (ρ). Forty-eight parturients fitted with 2 trackers also completed a walk exercise accompanied by a step-counting assessor, to evaluate accuracy, inter-, and intradevice reliability using interclass correlation (ICC).
Results:
Compared to step counting, activity trackers had high accuracy (ICC = 0.93) and excellent inter- and intradevice reliability (ICC = 0.98 and 0.96, respectively). Correlation analysis suggested that early ambulation is moderately correlated with postcesarean QoR-15 scores, with a ρ (95% confidence interval) equivalent to 0.56 (0.328-0.728). Regression analysis suggested that ambulation is a determinant of postcesarean QoR-15 scores, with an effect estimate (95% confidence interval) equivalent to 0.002 (0.001-0.003). Ambulation was also associated with all QoR-15 domains, except psychological support. The patient's acceptable symptom state (subjective threshold for good ambulation) in the first 24 hours was 287 steps.
Conclusions:
This study demonstrated the accuracy and reliability of activity trackers in measuring ambulation in clinical settings and suggested that postoperative ambulation is a determinant of postoperative QOR. A hypothetical implication of our findings is that interventions that improve ambulation may also help to enhance QOR, but further research is needed to establish a causal relationship.
Related Concept Videos
Reliability and Validity
Distribution Reliability and Automation
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...

