Related Experiment Video
Updated: Feb 3, 2026

In Vitro Model of Human Cutaneous Hypertrophic Scarring using Macromolecular Crowding
Published on: May 1, 2020
How Molecular Crowding Differs from Macromolecular Crowding: A Femtosecond Mid-Infrared Pump-Probe Study
Pramod Kumar Verma1,2,3, Achintya Kundu1,2, Minhaeng Cho1,2
1Center for Molecular Spectroscopy and Dynamics , Institute for Basic Science (IBS) , Seoul 02841 , Republic of Korea.
Abstract:
Crowding is an inherent property of living systems in which biochemical processes occur in highly concentrated solutions of various finite-sized species of both low (molecular crowding) and high (macromolecular crowding) molecular weights. Is molecular crowding fundamentally different from macromolecular crowding? To answer this question, we use a femtosecond mid-infrared pump-probe technique with three vibrational probes in molecular (diethylene glycol) and macromolecular (polyethylene glycol) solutions. In less crowded media, both molecular and macromolecular crowders fail to affect the dynamics of interstitial bulk-like water molecules and those at the crowder/water interface. In highly crowded media, interstitial water dynamics strongly depends on molecular crowding, but macromolecular crowding does not alter the bulk-like hydration dynamics and has a modest crowding effect on water at the crowder/water interface. The results of this study provide a molecular level understanding of the structural and dynamic changes to water and the water-mediated cross-linking of crowders.
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...

