How Molecular Crowding Differs from Macromolecular Crowding: A Femtosecond Mid-Infrared Pump-Probe Study

Pramod Kumar Verma1,2,3, Achintya Kundu1,2, Minhaeng Cho1,2

  • 1Center for Molecular Spectroscopy and Dynamics , Institute for Basic Science (IBS) , Seoul 02841 , Republic of Korea.

Related Concept Videos

ATP Driven Pumps III: V-type Pumps01:30

ATP Driven Pumps III: V-type Pumps

V-type pumps are ATP-driven pumps found in the vacuolar membranes of plants, yeast, endosomal and lysosomal membranes of animal cells, plasma membranes of a few specialized eukaryotic cells, and some prokaryotes. They are also known as the V1Vo-ATPase, that couple ATP hydrolysis to transport protons against a concentration gradient.
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
4.8K
ATP Driven Pumps II: P-type Pumps01:34

ATP Driven Pumps II: P-type Pumps

The P-type pumps are a large family of integral membrane transporter ATPases. They are divided into five major types based on substrate specificity, from I to V.
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
6.4K
Pumped Concrete01:13

Pumped Concrete

Concrete in large quantities can be pumped across long distances for placing in inaccessible sites. This system comprises a hopper that receives concrete from a mixer, a pump to propel the concrete, and pipelines that facilitate its delivery.
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
379
Refrigerators and Heat Pumps01:07

Refrigerators and Heat Pumps

Refrigerators or heat pumps are heat engines operating in a reverse direction. For a refrigerator, the focus is on removing heat from a specific area, whereas, for a heat pump, the focus is on dumping heat into one particular area. A refrigerator (or heat pump) absorbs heat Qc from the cold reservoir at Kelvin temperature Tc and discards heat Qh to the hot reservoir at Kelvin temperature Th, while work W is done on the engine’s working substance.
A household refrigerator removes heat from...
3.0K
Electric Potential and Potential Difference01:16

Electric Potential and Potential Difference

Suppose a positive test charge moves away from a positive static charge, then the Coulomb force does positive work, and its electric potential energy decreases. The potential energy per unit charge is defined as the electric potential. The electric potential is independent of the test charge.
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
5.7K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.3K