Related Experiment Video
Updated: Feb 3, 2026

Author Spotlight: Exercise Test for Evaluation of the Functional Efficacy of the Pig Cardiovascular System
Published on: May 12, 2023
Bioequivalence evaluation of two 5% ceftiofur hydrochloride sterile suspension in pigs
Jincheng Xiong1,2, Qianqian Zhu1,2, Zhixin Lei1,2
1Department of Veterinary Pharmacology, College of Veterinary Medicine, Huazhong Agricultural University, Wuhan 430070, China.
Abstract:
The purpose of this study was to evaluate the bioequivalence of 5% ceftiofur hydrochloride sterile suspension in two formulations, a test formulation (Saifukang 5% CEF, Hvsen) and a reference formulation (Excenel®RTU 5% CEF, Pfizer). Twenty-four healthy pigs were assigned to a two-period, two-treatment crossover parallel trial, and both formulations were administered at a single intramuscular dose of 5 mg/kg weight, with a 7-day washout period. Blood samples were collected consecutively for up to 144 hr after administration. The concentrations of ceftiofur- and desfuroylceftiofur-related metabolites in the plasma were determined by high-performance liquid chromatography. In addition, the major pharmacokinetic parameters (Cmax, AUC0-t and AUC0-∞) were computed and compared via analysis of variance, with 90% confidence intervals. Bioequivalence evaluation of Tmax was statistically analyzed with the nonparametric test. The comparison values between test and reference formulation for AUC0-t, AUC0-∞, Cmax, and Tmax were 376.7 ± 75.3 µg·hr/ml, 390.5 ± 78.6 µg·hr/ml, 385.9 ± 79.2 µg·hr/ml, 402.7 ± 80.4 µg·hr/ml, 34.6 ± 5.5 µg/ml, 36.1 ± 6.2 µg/ml, 1.27 ± 0.18 hr, and 1.26 ± 0.21 hr, respectively, and we observed no significant differences between the two formulations. The 90% CI values were within the recommended range of 80-125% (P>0.05), and the relative bioavailability of the test product was 96.47 ± 10.92% according to AUC0-t values. Based on our results, the two formulations exhibit comparable pharmacokinetic profiles, and the test product is bioequivalent to the reference formulation.
Related Concept Videos
Bioequivalence: Overview
Bioequivalence studies: Biowaivers
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Equivalence: In Vitro and In Vivo Bioequivalence